8
Operation Procedures
Knowledge of the proper operation of the M3-200H is required to ensure
user safety and efficient performance of the extractor.
SET UP AND OPERATION
1. Electrical Cords:
Two 25’ power cords are supplied with the Olympus M3-200H. Cord #1 powers Vacuum Motor #1and
heater element #2; Cord #2 powers the Solution Pump, Vacuum Motor #2 and heater element #1. The
amperage required by each cord requires that the two cords be plugged into separate 20amp circuits.
Plug the two power cords into two outlets from different circuits.
If you are not sure if you are connected to separate circuits, use a Breaker Buddy (item # AX49), available
from Hydro-Force, to test your circuits in the following manner:
•
Plug the cords into the two outlets being tested, and then plug the Breaker Buddy into the two cords.
•
If the green indicator light fails to light, you may be on the same circuit and must select a different
plug for one of the cords.
•
If the green indicator light comes on, you are plugged into two different circuits; connect the cords to
the machine and proceed with your set-up procedure.
If a circuit breaker trips during operation, reset the breaker and move the cord to another outlet as needed.
Section
2
Power Cord – AX32
25’ – 12 gauge M-F Plugs
Breaker Buddy – AX49
Cord #2
Cord #1