background image

  40 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15 

18 

20 

21 

22 

23 & 23A 

24 

 

32 

32 

37 

38 

39 

40 

40 

55 & 56 

 

40 

41 & 64 

55 & 56 

CONTROL PANEL  

REAR VIEW - BASE & BASE SKIRT  

HINGE SCREWS 

25 

17 

Summary of Contents for Nautilus Extreme MXE-200

Page 1: ...1 LMANN20 Revised 02 16 2018 Nautilus MXE 200 Operating Manual EXTREME ...

Page 2: ...m Connections 8 Electrical Supply 9 Water Supply Chemicals 10 Solution Hose Pump Priming 12 Vacuum Hose 14 Foam Downer 15 Pump Out System 16 Shutdown Procedures 17 Accessory Storage 18 Troubleshooting 19 Solution Flow Path 22 Wiring Diagrams 23 SECTION 3 Maintenance Technical Maintenance 26 Drawings Parts Lists o Pump 34 o Pressure Regulator 35 o Auto Fill 36 o Pump Out Pump 38 o Parts Pictures 39...

Page 3: ...fely to understand how to properly operate and maintain the machine and to ensure that the equipment operates at its maximum performance level All users must read and understand this manual completely before operating the machine Always maintain this manual in legible condition adjacent to the Nautilus Extreme MXE 200 or place in a secure location for future reference Any questions pertaining to t...

Page 4: ...Out Pump Standard Equipment Vacuum Connection 2 Barb or 2 Male Flash Cuff with 2 Male NPT Vacuum Hose 25 X 1 1 2 with 1 1 2 cuff 2 cuff 2 Female Flash Cuff x 1 1 2 hose adapter Carpet Wand 1 1 2 SS Dual Jet S Bend Wand AW29 Accessory Mount Hardware Four 1 4 20 x 5 8 SS Screws and Washers HP Solution Hose 25 x 1 4 with 1 4 male female quick connects Pump Priming Hose 12 x 1 4 with 1 4 male quick co...

Page 5: ...uff for 1 1 2 Vac Hose AH46 1 1 2 cuff for 1 1 2 Vac Hose AH42 1 1 2 Hose Connector PVC AH74 HP Solution Hose 1 4 X 25 w M F Quick Connects AH79D 1 4 Male Quick Connect AH102B 1 4 Female Quick Connect AH101B Pump out Hose AH65 Hydro Filter II AC10 Replacement Screen for Hydro Filter II AC10C Metering Tip Kit PDE001 12 3 X 25 Power Cord 1696 6412 12 3 X 50 GFCI Power Cord NM4407A Belt Pack AX108 AC...

Page 6: ...on as the plug No plug adapter should be used with this machine The power cords supplied with this machine are properly sized to handle the electrical load of this machine and properly grounded as described above Any extension cords used with this machine must be similarly sized with an equal or greater load rating and grounded to assure safe operation A properly sized or rated GFCI protected cord...

Page 7: ...es above 130ºF Rinse the solution tank chemical system and pump with fresh water after each day s use Do not allow pump to run dry Always maintain adequate solution level to supply solution pump HP hoses may rupture if worn or damaged Do not use HP solution hoses if hose covering is cut bulging or otherwise damaged Examine HP solution hoses daily and replace or repair hoses as needed Use a Hydro F...

Page 8: ...el 1 Connect the discharge exhaust hose from vacuum 1 to the exhaust pipe on machine base 2 Place the rubber stopper into the vacuum inlet port of vacuum manifold number two 3 Open vacuum gate valve and attach the Gatekeeper to prevent accidental valve closure When connected in parallel both vacuums must be running during cleaning Vacuums cannot be operated individually To connect vacuums in serie...

Page 9: ...ircuit during operation 20amp circuits may be required 20amp circuits are usually found in kitchens and bathrooms An overloaded circuit will not always trip the circuit breaker immediately but may not provide sufficient voltage for proper operation and the breaker may trip eventually Plug the two power cords into two outlets from different circuits If the Dual Circuit Indicator green light fails t...

Page 10: ...led by the metering tip and the dilution rate can only be changed by changing the metering tip See How to Change the Metering Tip on Page 11 for instructions Chemical Feed Setup Remove the chemical feed hose from the solution tank Make sure float is attached to valve and hanging freely above the bottom of the solution tank Adjust float height to maintain adequate water level Place the end of the c...

Page 11: ... rates are based on chemicals with water like viscosity Thicker more viscous chemicals will dilute at a different rate For powdered chemicals a liquid concentrate must be made Mix the concentrate according to the manufacturer s directions and then select the appropriate metering tip Contact your distributor or Hydro Force if you have questions about your chemical Metering Tip Application Chart Met...

Page 12: ... to the float valve Unhook the float from the beaded chain on the valve Unsnap the hook from the beaded chain on the float Move the bottle down to decrease the water level Move the bottle up to increase the water level Snap the back onto the float chain hook the float back onto the valve chain Turn the water supply back on If the chemical is not drawing or if the tank is not filling or is overflow...

Page 13: ...f flow is low or unsteady check the hose from the solution tank to the pump as well as the filter for clogging kinks or restrictions Clean or replace hose and or filter and repeat the priming procedure If you are having trouble with the pump refer to the trouble shooting guide or contact your distributor for advice or assistance 4 Connection of Solution Hose Connect the high pressure solution hose...

Page 14: ...ct the 1 1 2 vacuum hose to the 2 hose barb on the machine With the proper cuff attached to the 25 Vacuum Hose the 25 vacuum hose is then connected to the vacuum connection port on the MXE 200 The other end with the 1 1 2 cuff is connected to the cleaning tool When ready to begin cleaning turn both vacuum switches to the ON position If connected in series the MXE 200 can be operated with only one ...

Page 15: ...mically NO LABOR is involved to spray or spread defoamer it s all automatic Keeps silicone defoamers off the floor where they can cause resoiling problems The Foam Downer is an attachment that allows the vacuum to draw a small amount of defoamer in a constant slow flow into the waste tank of the Nautilus We recommend using a diluted defoaming solution of four ounces of defoamer to one gallon of wa...

Page 16: ...float switch The pump will turn ON OFF during normal operation Pump will be damaged if allowed to run dry When ready to begin cleaning turn the Waste Pump switch to the ON position If not using the waste pump out the pump out hose does not need to be connected When the recovery tank fills during cleaning the float assembly in the vacuum inlet filter will rise and will automatically shut off the va...

Page 17: ...the vacuum hose and solution hose from the machine If water remains in the solution tank use the vacuum hose and vacuum the excess water from the tank If the optional auto fill system was utilized place the chemical feed hose back into the solution tank If the optional Auto waste pump out system was used o Turn the waste pump switch on lift float switch to pump out any remaining water from the rec...

Page 18: ...0 has two sets of cord wraps to hold two 12 3 x 50 power cords Carpet Wand Storage The front of the MXE 200 is designed to hold a S Bend Carpet wand and has two straps to hold it securely Optional strap for larger wands available Other Tool Hose Storage Each side of the MXE 200 has a set of molded in threaded inserts to which holders can be attached to hold other accessories or supplies making it ...

Page 19: ... Pulsation Solution inlet filter plugged Clean or replace filter Hose from solution tank restricted Repair or replace hose Pump intake hose or fittings leaking Repair or replace hose Tighten clamps or replace fittings Pressure regulator sticking Lube seal on regulator piston Pressure regulator faulty Repair or replace pressure regulator 1683 5656 Filter screen or jets plugged on tool Clean out fil...

Page 20: ...Replace gasket PA010A Recovery tank lid gasket damaged Replace lid or gasket 1650 5695 or 1663 5397 Drain valve open Close valve Drain valve leaking Repair or replace drain valve PEA11 Vacuum motor hoses loose leaking Reconnect or replace vacuum motor hoses Vacuum Valve in wrong Position Check Vacuum Gate Valve Position PAGE 8 Vacuums not connected properly See vacuum connection instructions PAGE ...

Page 21: ... connects AH101B AH102B Solution tank Float too heavy Filled with water Replace float overflowing Float chain tangled Make sure float chain free hanging properly Float too high Adjust chain to set float at proper level Water Pressure too high Use pressure regulator on auto fill hose Float valve faulty Repair or replace float valve Chemical Jug Foot valve in Filter stuck Clean out foot valve and fi...

Page 22: ...uick Connect Chemical Jug Denotes Water flow in high pressure hose Denotes Chemical flow Denotes by pass water flow from pressure regulator Denotes incoming water flow MXE 200 Solution Flow Path Optional Auto Fill Float Valve Assembly Optional Auto Fill Inlet Quick Connect ...

Page 23: ...23 M1200 Wiring Diagram Nautilus MXE 200 Wiring Diagram Cord 1 ...

Page 24: ...24 VAC 1 PUMP OUT SOL PUMP Machine Base Dual Circuit Indicator VAC 2 PUMP OUT CORD 2 VAC 2 12 3 Nautilus MXE 200 Wiring Diagram Cord 2 FLOAT SWITCH ...

Page 25: ...witch Power from Cord 2 Do not turn Waste Pump Switch ON unless a hose is connected to the Pump out Outlet port If the Float switch is down the pump will not turn on when the switch is turned on When the water level gets high enough the Float switch will turn the waste pump on and off again when the level drops Vacuum 1 Power from Cord 1 When the switch is turned to the ON position power is suppli...

Page 26: ...g switches or power cords Failure to do so may result in severe personal injury or death OPERATION INTERVAL Page CLEAN CHEMICAL FEED FILTER FOOT VALVE Daily After Each Job 27 CLEAN VACUUM SHUTOFF ASSEMBLY SCREEN Daily After Each Job 27 CLEAN HYDRO FILTER II Daily After Each Job 28 RINSE OUT RECOVERY TANK Daily 28 CLEAN WASTE PUMP OUT PUMP Daily 29 FLUSH SOLUTION TANK AND PUMP Daily 29 CLEAN PUMP I...

Page 27: ...vacuum motors Operating the MXE 200 without the Vacuum Shutoff Assembly or with a poorly maintained assembly will greatly decrease the life of the vacuum motors and will void the warranty If debris builds up on this filter it will reduce the vacuum air flow and may cause a significant decrease in the rate of water recovery If debris prevents the float from moving or seating against the Filter Cap ...

Page 28: ...th clean water Examine the o ring lid seal and replace as needed Re install the new or cleaned screen Screw the lid back onto the body and turn clockwise to tighten RINSE OUT RECOVERY TANK Build up of fine silt sand and other debris in the recovery tank can damage the Drain Valve and Waste Pump if so equipped Hair and fibers in the recovery tank can clog the vacuum filter and Pump out filter if so...

Page 29: ... water into the solution tank With Cords 1 2 plugged in connect the pump prime hose to the solution outlet female quick connect Direct the end of the pump priming hose into the recovery tank vacuum barb Turn one or both of the vacuums ON and turn the solution pump ON Let the pump run until most of the water has been pumped out of the solution tank Do not let the pump run dry Turn the pump OFF befo...

Page 30: ... FILTER A restricted Pump Inlet Filter can prevent the solution pump from providing adequate pressure for cleaning A restriction or air leak on the pump inlet hose can also damage the solution pump check valves and plunger seals To examine the filter open the solution tank lid on the front of the machine The filter is in the bottom of the solution tank Grasp the filter cap and unscrew the filter f...

Page 31: ...as been drawn through the proportioner and mixed with the incoming water The metering tip can be removed from the proportioner to speed up the process Once the rinse solution has been drawn through the proportioner turn off the water faucet and disconnect the Auto Fill Water Supply Hose Plug in Cord 1 connect the vacuum hose to the vacuum barb turn on one or both vacuums and use the vacuum hose to...

Page 32: ...de for deep scratches Deep scratches will allow water to flow past gaskets and leak from valve Replace valve if needed Examine the gaskets and replace if cut torn or deformed Raised rounded side of gasket goes toward valve slide Larger flat sides seat on ring on flange and outlet adapter Sand and debris will collect in the bottom of the valve body and prevent the slide from going down and seating ...

Page 33: ...etering tip can be removed 3 Turn the solution pump switch to the ON position and allow the anti freeze to circulate for 5 10 minutes Mix and add more anti freeze solution as needed For machines with the optional Auto Fill System make sure end of chemical feed hose stays submerged in the anti freeze solution This will assure that the anti freeze will be drawn into the proportioning valve 4 Connect...

Page 34: ...34 Parts Replacementpartsavailableforrepairof yourMXE 200 Section 3 KIT A PT022 KIT B PT051 KIT C PT030 MXE 200 PUMP AP51 PARTS ASSEMBLY 1 1 1 2 2 2 2 5 9 9 3 8 7 6 6 ...

Page 35: ...1 4 20X1 SHCS SS 7 MOUNT BOLT 4 BOLT 1 4 20X2 1 2 SHCS SS 8 WASHER FLAT M6 STAINLESS STEEL 10 WSH FLAT M6 SS 9 NUT 20 NYLOCK HEAD BOLT 6 NUT 1 4 20 NYLOCK ZP NS PUMP COMPLETE WITH MOTOR 1 AP51 NS PUMP WITHOUT MOTOR 1 PT047 NS MOTOR 1 PT004 PUMPTEC 114 PUMP AP51 DESCRIPTION 1 REGULATOR COMPLETE 1683 5656 2 REGULATOR BODY 3 PISTON 4 PISTON SEAL 5 SPRING PLATE 6 SPRING 7 KNOB NS REPAIR KIT INCLUDES 3...

Page 36: ...36 OPTIONAL AUTO FILL ASSEMBLY M013 NM5740 Float Valve Assembly See Parts Breakdown on Next Page BR286 BR286 BR138 NM5751 NM5751 BR282A AH102B BR282A ...

Page 37: ...37 OPTIONAL AUTO FILL FLOAT VALVE ASSEMBLY NM5740 ...

Page 38: ...38 Pump Out Pump PARTS ASSEMBLY ...

Page 39: ...39 1 4 4 6 7 8 9 10 11 3 3 8 9 12 8 9 39 8 9 2 2 5 ...

Page 40: ...40 2 8 15 18 8 20 21 22 23 23A 24 32 32 37 38 39 40 40 55 56 40 41 64 55 56 9 CONTROL PANEL REAR VIEW BASE BASE SKIRT HINGE SCREWS 9 25 9 17 ...

Page 41: ...41 27 27A 28 29 29 31 31 9 9 32 32 33 125 120 37 1 39 13 14 14A 30 30 26 REAR VIEW BASE BASE SKIRT RECOVERY TANK VACUUM PLUG ASSEMBLY 109 106 107 108 121 38 126 36A ...

Page 42: ...42 32 43 119 37 46 44 47 48 53 TOP VIEW OF BASE 3 58 59 55 56 55 56 46 3 58 59 47 110 16 32 110 43 51 119 118 9 50 9 50 52 118 ...

Page 43: ...43 51 47 47 47 47 52 37 9 54 64 9 54 64 52 VACUUM MOUNTS CONNECTIONS 16 3 58 59 48 49 49 52 46 46 9 54 64 107 106 108 109 81 51 9 50 ...

Page 44: ...44 60 3 58 59 57 BOTTOM VIEW OF BASE 3 58 59 37 9 54 64 9 54 64 61 62 63 55 39 56 55 PUMP 60 3 58 59 16 9 64 113 69 117 45 116 71 68 119 44 118 124 ...

Page 45: ...45 9 41 2 BOTTOM VIEW SOLUTION TANK BASE SKIRT 72 1 73 9 9 8 8 39 74 75 76 77 77 30 30 125 123 31 36A 126 75 122 ...

Page 46: ...46 2 39 73 73 70 9 30 31 82 2 83 82 84 INSIDE SOLUTION TANK BOTTOM VIEW SOLUTION TANK 9 30 31 88 68 69 89 51 116 117 72 79 1 ...

Page 47: ...47 85 86 87 101 86 102 1 VACUUM SHUTOFF ASSEMBLY INSIDE RECOVERY TANK WITHOUT OPTIONAL PUMP OUT 85 87 111 ...

Page 48: ...6 87 91 92 94 99 9 64 97 98 100 101 86 102 103 PUMP OUT CORD OUTLET FITTINGS LOCATED BEHIND CONTROL PANEL VACUUM SHUTOFF ASSEMBLY INSIDE RECOVERY TANK WITH OPTIONAL PUMP OUT 85 87 95 112 111 93 1 114 115 96 94 ...

Page 49: ...49 92 91 95 94 112 13 14 14A 104 105 1 39 PUMP OUT CONNECTIONS ...

Page 50: ...50 35 36 36A 78 36 36A 34 39 127 128 129 2 1 130 32 34 119 39 131 ...

Page 51: ...ASHER LOCK SS 10 NM5840 WAND HOLDER STRAP LONG TOP STRAP 31 NM4063 SCREW 20 X SOCHD SS 11 NM5844 WAND HOLDER BUCKLE 32 NM5722 WHEEL 12 with HUB CAP 12 NM5842 WAND HOLDER STRAP SHORT BOTTOM STRAP NS NM5010 AXLE CAP PUSH NUT Secure wheel to axle 13 BR319 ADAPTER MPT X MGH 33 NM4447 GREEN NEON LIGHT 120V 14 BR325 GARDEN HOSE CAP 34 NM6120 COOLING FAN 120MM 14A BR600 GARDEN HOSE WASHER 35 NM6122 PLAST...

Page 52: ...0MM 53 NM5705X DECAL VAC CONNECTION 79 NM5025 RIVET VAC HOSE END 54 NM5141 SCREW 20 X 3 25 SOCHD SS 80 NM5124 SCREW 8 32 X PPH SS 55 NM5793 NUT 8 32 NYLOCK SS 81 NM4472 CLAMP W THUMB SCREW 56 NM5124 SCREW 8 32 X PPH SS 82 NM5098 BULKHEAD FITTING 3 8 57 NM5752C LATCH SLIDE QTY 2 83 BR284 ELBOW 90DEG 3 8 STREET 58 NM5120 SCREW 5 16 18 X 3 4 HXHD SS 84 PP14 806504 ACORN STRAINER FPT 59 PFA10 NUT 5 16...

Page 53: ... 104 BR278 ELBOW 45DEG STREET 129 PA184 SCREW 8 X 3 8 SELF TAP PPH SS 105 BR049 BARB X FPT 130 NM5711 DECAL NAUTILUS SIDE QTY 2 106 PHY106 028 RUBBER VACUUM PLUG 131 NM5933 3 16 INT STAR WASHER SS Cooling Fan Ground 107 NM4263 SCREW TEK 10 X 5 8 SS NS NM5703 WIRING HARNESS UPPER 108 NM4460 CABLE NS NM5701 WIRING HARNESS LOWER 109 NM4462 SLEEVE 7 CABLE CLAMP NS BR020 BARB 3 8 X MPT 110 NM5125 WASHE...

Page 54: ...HOSE CLAMP PH07 SOLUTION HOSE 2 REGULATOR TO SOLUTION TANK 3 8 ID CLEAR COIL NM5082 SOLD PER INCH 35 BOTH ENDS HOSE CLAMP NA2250 SOLUTION HOSE 3 PUMP TO HP SOLUTION HOSE 3 8 ID LP HOSE NM4340 SOLD PER INCH 33 BOTH ENDS HOSE CLAMP NA2250 HP SOLUTION HOSE OUTLET QC TO HOSE 3 HP HYDROCOIL AH79CF SOLD PER FT 19 2 QC END XAF1 M JOINT END XAF2 FM DRAIN HOSE REC TANK TO PUMP OUT OUTLET CLEAR COIL NM5093 ...

Page 55: ...nty shall not apply to defects resulting from improper operation lack of maintenance unauthorized modification chemical incompatibility misuse abuse or exposure to freezing temperature conditions It does not cover normal wear items such as o rings valve seals pump seals hoses jets cords batteries or other items which require replacement as a result of ordinary usage To obtain warranty service for ...

Reviews: