![Hydro-Force Nautilus Extreme MXE-200 Operating Manual Download Page 19](http://html.mh-extra.com/html/hydro-force/nautilus-extreme-mxe-200/nautilus-extreme-mxe-200_operating-manual_2191934019.webp)
19
Troubleshooting –
Nautilus Extreme MXE-200
Problem
Cause
Solution
Machine not
Building circuit breaker tripped.
Reset breakers or move cords to other outlets
turning on -
Faulty power cord
Replace cord (
1696-6412
)
No power
Faulty switches or internal wiring
Check wiring & test switches - Repair as needed *
Solution
Pump
Building circuit breaker tripped.
Reset breakers or move cords to other outlets
not running
Pump circuit breaker tripped
Reset breaker – Check available circuit power & pump
Faulty power cord
Replace cord (
1696-6412
)
Faulty switches or internal wiring
Check wiring & test switches - Repair as needed *
Pump motor breaker tripped
Push in reset button on pump motor &/or external breaker
Pump motor faulty
Replace pump motor (PT061)
Pump seized - trips breaker
Repair or replace pump head (PT047) or bearing (PT030) -
Check motor and/or replace complete pump & motor assy.
(AP51)
Low Solution
Jets too large for pressure desired
Check jets size & flow rates use smaller jets or lower
pressure
Pressure
and/or
Jets worn allowing too much flow
Replace jets
Pulsation
Solution inlet filter plugged
Clean or replace filter
Hose from solution tank restricted
Repair or replace hose
Pump intake hose or fittings
leaking
Repair or replace hose. Tighten clamps or replace fittings
Pressure regulator sticking
Lube seal on regulator piston
Pressure regulator faulty
Repair or replace pressure regulator (
1683-5656
)
Filter screen or jets plugged on
tool
Clean out filter or jets
Solution tank empty
Add water to tank - Check & repair auto fill assembly
Pump not primed
Perform pump priming procedure
Pump faulty
Repair or replace pump (PT047 or AP51)
Tool valve faulty
Repair or replace valve
Quick connects or hoses restricted Clean out or replace quick connects and/or hoses
Can't connect
Pressure in lines
Release pressure
solution hose
Quick connects faulty
Replace quick connects (AH101B, AH102B)
to machine
Wrong style/size quick connects
Replace quick connects to match connects on machine
*
: To reduce the risk of fire electrical shock or injury repairs to wiring should only be
performed by experienced service technicians.
If you are not experienced in checking electrical wiring contact your nearest authorized service
center to perform tests and repairs to wiring and switches.
Section
2
Troubleshooting
Summary of Contents for Nautilus Extreme MXE-200
Page 1: ...1 LMANN20 Revised 02 16 2018 Nautilus MXE 200 Operating Manual EXTREME ...
Page 23: ...23 M1200 Wiring Diagram Nautilus MXE 200 Wiring Diagram Cord 1 ...
Page 37: ...37 OPTIONAL AUTO FILL FLOAT VALVE ASSEMBLY NM5740 ...
Page 38: ...38 Pump Out Pump PARTS ASSEMBLY ...
Page 39: ...39 1 4 4 6 7 8 9 10 11 3 3 8 9 12 8 9 39 8 9 2 2 5 ...
Page 49: ...49 92 91 95 94 112 13 14 14A 104 105 1 39 PUMP OUT CONNECTIONS ...
Page 50: ...50 35 36 36A 78 36 36A 34 39 127 128 129 2 1 130 32 34 119 39 131 ...