background image

 

 

WATER INLET  FITTING - 

The Hydro-Well III gives you the option of mounting the 

water inlet fitting on the top of the tank on either the right or left side of the tank. Choose the 
location on the top right or top left side of the tank that best suits your layout and to install the 

Float Valve Assembly inside the tank. 

 

 

Apply Teflon Tape to the threads on both ends of the 1/2” x 4” SS Nipple (NM5825).  Attach the 
1/2” F-F 90º Elbow (BR296) to one end of the 1/2” x 4” SS nipple.   

 

Reach inside the tank and thread the other end of the nipple into the 1/2” female pipe thread end 

of the bulkhead fitting on the top of the tank. Tighten the nipple so it will not leak, and turn the 
nipple so the elbow points toward the back of the tank. (Do not over-tighten nipple. bulkhead 

fitting can be damaged if over-tightened.) 

 

Apply thread sealant to the male threads on the Float Valve (PBL23025).  
(Do not attach Float Arm and Float ball until after Valve is installed.) 

 

Thread the Float Valve into the 1/2” F-F 90º Elbow. Tighten the Float Valve so it will not leak, 

and turn the valve so the outlet port is pointing down.  

Attach the Float Arm & Float Ball Assembly to the Float Valve. Adjust Position of Float Arm to 

shut off flow before water level reaches the Tank Vent/Overflow port on the side of the tank. 

Apply thread sealant to the male threads on the 1/2” M-F Elbow (BR286). Thread the elbow into 

the 1/2” female pipe thread on the bulkhead fitting on the outside of the molded in fitting on top 
of  the  tank  where  you  just  installed  the  Float  Valve  Assembly.  (Do  not  over-tighten  elbow. 

Bulkhead fitting can be damaged if over-tightened. This damage will not be covered under the 

product warranty)  

You can now connect the appropriate inlet fitting to connect to your water supply hose, such as a 
garden hose fitting or quick connect. (Quick connects or other hose connection fittings are not 

included with the Hydro-Well III.)  

Apply  thread  sealant  to  one  of  the  PVC  1/2”  Hex  Plugs  (BR226P).  Thread  the  plug  into  the 

unused water inlet port on the other side of the tank. 

 

Tank Preparation 

Water Inlet Port – Right Side 

½” Hex Plug PVC – BR226P 

Summary of Contents for 1609-8636

Page 1: ...1 1609 8636 HYDRO WELL III 100 GALLON FRESH WATER TANK Hydro Force Manufacturing 4282 South 590 West Salt Lake City UT 84123 801 268 2673 801 268 3856 FAX Revised 01 09 2020 LMANAX139 ...

Page 2: ...III is designed for use with cold water hot water from residential or commercial building water heaters may be safely used if the incoming water temperature is below 150ºF or 65ºC However if you are using hot water make sure the water temperature in the tank does not exceed the temperature rating of your pump Check with the pump manufacturer or your distributor for information on the temperature r...

Page 3: ...floor mat can absorb hold water causing accelerated rusting of the van floor and allowing growth of mold and mildew The removal of the felt backing before installing the Hydro Well III is recommended The most stable installations are achieved when the Hydro Well III is installed on top of a flat smooth floor This can be accomplished by installing a floor made of 1 2 or 3 4 exterior grade or marine...

Page 4: ... the Float Valve into the 1 2 F F 90º Elbow Tighten the Float Valve so it will not leak and turn the valve so the outlet port is pointing down Attach the Float Arm Float Ball Assembly to the Float Valve Adjust Position of Float Arm to shut off flow before water level reaches the Tank Vent Overflow port on the side of the tank Apply thread sealant to the male threads on the 1 2 M F Elbow BR286 Thre...

Page 5: ... if fittings are over tightened This damage will not be covered under the product warranty Apply thread sealant to the 1 2 pipe threads on the 3 4 Hose Barb BR044 Thread the barb into the elbow Tighten enough so it will not leak but do not over tighten Apply thread sealant to one of the PVC 1 2 Hex Plugs BR226P Thread the plug into the unused water outlet port on the other side of the tank If desi...

Page 6: ...ydro Well III Tank Vent Overflow Fittings must be installed to protect tank from damage due to overfilling or over pressurizing Failure to install the Tank Vent Overflow Fittings will void the Hydro Well III warranty Only fill the Hydro Well III while vehicle is parked on a level surface Pressure regulator must be used on hose when filling tank There are two Overflow Ports one on each side of the ...

Page 7: ...he two floor brackets to the floor One bracket on each end of the tank All three hold down rods Two on the front one on the back must also be installed The floor brackets have four holes available to allow some flexibility in bolt placement For the most stable mounting use the two outside holes The farther apart the bolts are the more stable the bracket will be There is also a little flexibility i...

Page 8: ... the bracket over the edge of the tank and tighten the tap bolt and move the jam nut as needed to adjust the height of the hold down assembly Leave extra threads open between the tap bolt and coupler and coupler and rod for later adjustments if needed Adjust rod height to secure the bracket to the tank such the bracket and tank will not move but not too tight Over tightening the hold down rod may ...

Page 9: ... Under the van place back up plate on each bolt and secure to floor using the 3 8 lock washer and 3 8 nut 9 Connect inlet water fittings water supply pump overflow fittings outlet water fittings and hoses as needed 10 Fill tank 1 3 full of water and check hold down rods and re tighten as needed Check for leaks drain tank and reseal fittings as needed 3 8 11 10 13 14 3 AP36 AP38 ...

Page 10: ...INLINE FILTER WITH HOSE BARBS PF20381 010 ELBOW BARB FOR FLOJET QUAD PUMPS PF20381 006 STRAIGHT BARB FOR FLOJET QUAD PUMPS AH60 ID WATER HOSE SOLD PER FOOT PAF01 3 8 MALE QUICK CONNECT BRASS PAF02 3 8 FEMALE QUICK CONNECT BRASS BR030 HOSE BAR X 3 8 MPT BRASS BR284 ELBOW 90 DEG 3 8 M F STREET BRASS Drain Parts BR286 ELBOW 90 DEG M F STREET BRASS BR030 HOSE BAR X 3 8 MPT BRASS BR136 REDUCING HEX NIP...

Page 11: ... 16 x 75 ZINC PLTD 4 10 NM4368 WASHER LOCK 3 8 SPLIT ZINC PLTD 14 11 PA189 WASHER 3 8 ZINC PLTD 8 13 NM5818 BACK UP PLATE BRACKET HYDRO SHELF 7 14 NM4366 NUT 3 8 16 HEX ZINC PLTD 7 17 1650 5695 LID ASSEMBLY 8 INCH W DECK 2 NS 1663 5397 GASKET FOR 8 LID DECK 2 18 PA187 SCREW 10 X 5 8 PPHD SS 12 19 PBL23025 FLOAT VALVE 1 20 NM5825 NIPPLE 1 2 X 4 SS 1 21 BR226P PLUG 1 2 HEX PVC 3 22 BR044 BARB 3 4 X ...

Page 12: ...12 Hydro Well III Parts ...

Page 13: ...13 Hydro Well III Parts Attachment detail under Van floor ...

Page 14: ...OLD PER FT 23 ELBOW 90 DEG M F 3 8 MALE QUICK CONNECT REDUCING NIPPLE X 3 8 REDUCING NIPPLE X 3 8 HOSE CLAMP PH09 ID HOSE SOLD PER FT 3 8 BALL VALVE ADAPTER 3 8 MPT X MGH 22 BARB X MPT ELBOW 90 DEG M F Indicates item is not included with Hydro Well III Indicates item is not included with Hydro Well III 23 ELBOW 90 DEG M F 24 BULKHEAD FITTING GARDEN HOSE CAP WASHER ...

Page 15: ...s 19 FLOAT VALVE FPT INLET 27 THREADED ROD 1 4 20 X 1 3 4 SS PRESSURE REGULATOR INLINE NM5823 20 NIPPLE X 4 SS 28 NUT 1 4 20 HEX SS 26 FLOAT BALL 4 X 5 POLY 25 ELBOW 90º F F BRASS TANK VENT OVERFLOW PORT FLOAT VALVE ASSEMBLY ...

Page 16: ...or heat sources such as space heaters water heaters truck mount engines To obtain warranty service for the Hydro Well III contact your distributor or Hydro Force If the tank must be returned to Hydro Force or an authorized service center the purchaser shall prepay shipping charges for products returned for warranty service No returned items will be accepted by Hydro Force without prior authorizati...