7. Operating the digital gauge

The maximum load capacity of the MAN-SD1S-C transducer at the base of the gauge is 

0–145kN and the gauge should not be loaded above this figure as permanent damage will 

occur. Eventually the battery will require replacement (when warning indicator comes on) 

and the battery fitted under the removable cover on the back of the gauge. Replace with 

type PP3 9 volt unit.

Operate Gauge in ‘Normal rise and fall’ mode

Press button 

 

to switch gauge on to ‘Normal rise and fall mode’. 

This will give a load reading in kN rising as the operating handle on the 

tester is turned clockwise. By turning the handle anti-clockwise the load 

 

will decrease and show the reading decreasing.

Press 

 

to switch off gauge when finished.

Operate Gauge in ‘Peak Hold’ mode

1.  Press button 

 to switch gauge on 

2. Press   then 

 

. On display ‘OFF’ will appear.

3. Press   

twice to display MAX. 

4. Press   

to display PASS.

5. Press   and   together for about 3 seconds then release. 

A small vertical arrow      will appear in left hand side of screen.

6.  To zero reading press 

 and wait 2 seconds.

  Gauge is now in peak hold mode and will display the maximum 

 

load achieved and retain this even when the load has decreased.

  Return to ‘Normal rise and fall’ mode

1. Press   then 

 

and display shows MAX.

2. Press   

and display reads OFF.

3. Press   twice and display reads 0.
4. Press   and   together twice until display reads - 0.0

  (The last digit may not read 0 due to ambient temperature.)

Press 

 to switch off gauge.

To Zero the gauge

If the gauge is reading a small 

amount (0.32 for example) when 

no load is applied - use the 

following instructions to re-set the 

display to zero.
First release any pressure held in 

the Hydraulic Coupler by pushing 

in the pin at the base of the 

coupler.

Press 

 to turn on then 

, display=’Pdu’

Press 

 

display = ‘OFF’

Press 

 

display = ‘PASS’

Press 

 

display = ‘0’

Press 

 

until reading reaches ‘5’

Press 

 

display = ‘ZERO’

Press 

 

display = ‘SET’

Press 

 

display = ‘PSET’

Press 

 

display = ‘5’

Press 

 

display = ‘0.0’

8. Operating instructions for optional Bluetooth    

  Digital Gauge

Hydrajaws revolutionary digital technology 

captures test results using an Android OS 

mobile device and dedicated software ap

-

plication, allowing for instant visual graphs 

onsite for anchors & eyebolts. The digital 

system using Bluetooth produces real time 

visual graphs for each test.

A button and active LED on the top of 

 

the Model 2008 tester housing indicates 

that the tester is equipped with this feature 

(fig 18)

.

To switch on the Bluetooth element simply 

press the button and the LED light will 

eliminate and begin to flesh. Open the 

software application on the mobile device 

and select the tester gauge to establish a 

connection. When a Bluetooth connection 

has been established the LED will become 

constant.

Turn on the digital gauge as normal  

via the P button and operate as normal. 

Loadings will be visible on the tester 

gauge and results will be recorded on the 

mobile device*.

HYDRAJAWS

DIGITAL

The Bluetooth digital gauge can be retro 

fitted to a Model 2008 tester.

Fig 18

*Separate 

instructions for  

use of the Hydrajaws 

Bluetooth Digital  

will be provided. 

CAUTION:

DO NOT ZERO THE GAUGE 

WHEN IT IS UNDER LOAD.

Summary of Contents for 2008

Page 1: ...Operating Instructions HYDRAJAWS L I M I T E D 2008 Model Tester ...

Page 2: ... read before the tester is operated for the first time Always keep these operating instructions together with the tester Ensure that the operating instructions are with the tester when it is given to other persons TECHNICAL SPECIFICATIONS Intelligent digital pressure gauge 0 145kN 4 segment LCD display Accurate to 2 5 FSD Indication of pull out load Rise and fall output Maximum load achieved funct...

Page 3: ...ig 3 15 The bridge has been designed specifically for the model 2008 tester and directs reaction loads away from the fixing fig 1 The lightweight aluminium load spreading bridge fits in the carry case disassembled fig 2 The bridge is simple to assemble and adjust Three fully adjustable telescopic legs offer 11 height positions 25mm apart fig 3 The legs are held in place with steel ball pins The sw...

Page 4: ...ing on the gauge until it approaches zero Unwind the operating nut by hand until it is resting on the stop and unwind the adjustable nut and remove DO NOT CONTINUE TO UNWIND AGAINST THE STOP OTHERWISE SERIOUS DAMAGE WILL OCCUR Fig 5 Fig 6 2 General Testing Procedure set up 3 General Testing Procedure Operating the tester M20 connecting rod Threaded adaptor WARNING DO NOT unwind the piston past the...

Page 5: ...e re bar Failure to do this procedure may result in the tester running out of stroke 10mm fig 12 6 Ensure the tester is level by observing the spirit level on top of the tester case fig 13 4 Eyebolt testing 1 Screw the M20 connecting rod into the heavy duty clevis and ensure the thread engages fully so is flush with the block 2 Adjust the 3 telescopic legs on the bridge so that the pin lines up wi...

Page 6: ...ed 5 Secure the plate to the load spreading bridge with the x 2 M8 x 15 counter sunk screws fig 17 6 Spare screws are also provided for the tester assembly and bridge assembly 7 Operate the tester by using the M24 ratchet spanner to the desired load fig 14 8 Once the test is complete release the load fully and lower the threaded feet on each leg by turning the legs anti clockwise Full adjustment n...

Page 7: ...auge To Zero the gauge If the gauge is reading a small amount 0 32 for example when no load is applied use the following instructions to re set the display to zero First release any pressure held in the Hydraulic Coupler by pushing in the pin at the base of the coupler Press to turn on then display Pdu Press display OFF Press display PASS Press display 0 Press until reading reaches 5 Press display...

Page 8: ...home into position fig 26 5 To re assemble reverse procedure If Hydrajaws Bluetooth Digital is fitted A button and active LED on the top of the Model 2008 tester housing indicates that the tester is equipped with this feature then an extra cable needs to be disconnected 1 Follow procedure for removing dust cover gauge and battery 2 The data cable can be disconnected by pulling firmly fig 27 10 Cal...

Page 9: ...m B46 1JA UK Tel 44 0 1675 430 370 Fax 44 0 1675 465 950 email tester hydrajaws co uk www hydrajaws co uk HYDRAJAWS L I M I T E D FOR MORE INFORMATION ON HYDRAJAWS AND A FULL RANGE OF TESTING APPLICATIONS PLEASE VISIT THE WEBSITE AT WWW HYDRAJAWS CO UK ...

Reviews: