Performing maintenance
Performing maintenance
The WBF can be equipped with several clogging indicators, or optical or
electrical signal transmitters.
The clogging indicator shows how high the differential pressure over the filter
element/the filter bag is.
If the visual clogging indicator is red, the differential pressure is too high,
indicating that the filter element is used up and must be changed. The color
green indicates that the differential pressure over the filter element is <2 bar
and filtration will take place.
Filterelement / Filterbeutel wechseln
The Wombat filter housing can hold filter elements (1) or filter bags (2) with the
corresponding bar magnets.
Below you will find instructions on how to insert the filter element/filter bag:
From page 38
From page 45
WBF 16 bar
en(us)
Page 37 / 64
MoWa WBF 16bar 4031149a en-us 2016-02-25.doc