Reducer of Fluid oXidation
Technical data
Technical data
Air and water leaves the unit through the drain
adapter.Oil type must be approved by the
supplier.
Miscellaneous
Treats 2 m³ oil a day
Capacity
p
r
=
0,5 bar max.
Flow
Q=
4,5…6
dm3/min
Allowable pressure drop
Return line
Supply pressure:
18-22 bar
Connections G 3/4”
Oil viscosity range
1-2000 mm²/sec
Operation viscosity
1-100 mm²/sec cSt
Temperature:
-40ºC – +90ºC
Power demand:
75 W
Maximum oil volume: 4 dm3
Weight:
12 kg (when empty)
Number ..............................
Delivery date
..............................
General data
HYDAC FILTER SYSTEMS GMBH
us
Page 24 / 28
MoWa RFX 3570845 us 2010-08-20.doc