OLF-5 Series
Technical Data
HYDAC FILTER SYSTEMS GMBH
en
Page 48 / 52
BeWa OLF5_Serie 3433222b en-us 2011-11-14.doc
2011-11-14
Technical Data
Bypass-cracking pressure of filter
element
~ 3.5 bar
Operating pressure
~ 4.5 bar
Permissible Contamination:
< NAS 12
according to ISO4406:1999 class 23/21/18
Flow rate:
OLF-5/4
4 l/min
OLF-5-S
5 l/min
OLF-5/15
15 l/min
Viscosity range:
OLF-5-S
15 …150 mm²/s
OLF-5/4
15 … 7000 mm²/s
OLF-5/15
15 … 1000 mm²/s
Permissible suction pressure at
suction port connection (IN)
-0.4 … 0.6 bar
Fluid temperature range
0 … 80°C / 32 … 176°F
Ambient temperature
-20 … 40°C / -4 … 104°F
IP class
IP 54
Weight
~ 11.7 kg
Filtration rating
b (2)>1000 (
Δ
p 2.5 bar) for N5DM-filter
elements