OLF-5 Series
Changing the filter element – DIMICRON®
HYDAC FILTER SYSTEMS GMBH
en
Page 22 / 52
BeWa OLF5_Serie 3433222b en-us 2011-11-14.doc
2011-11-14
Changing the filter element – DIMICRON
®
1.
Switch off the system and close the locking
devices at the inlet and outlet ports
Make sure that the unit cannot be
inadvertently switched back on during
maintenance work.
2.
Put a suitable container (1) in place to catch
exiting medium.
Depressurize the filter housing.
Carefully open the drain plug (2) on the filter
bowl and empty the filter housing completely
using the drain screw (SW 6mm) on the
bottom of the filter housing.
The volume is ~ 2 liters.
After draining, replace the drain plug on the
filter bowl.
3.
Undo the housing clamp (1) on the filter
housing and then remove the housing by
moving it downwards (2).
Use an Allen wrench SW 6 mm (1).