Performing Maintenance
OFX
en(us)
Page 38 / 52
BeWa OFX 3796731 en-us 2014-03-31.doc
2014-03-31
accordance with the applicable
guidelines and regulations.
Dispose of the fluid in the filter
housing (2.6) in an environmentally
friendly manner.
6.
Clean the inside of the filter housing
(2.6).
7.
Lightly wet the seal ring on the new
filter element with operating
medium.
7.
Place the new filter element (7.0) in
the filter housing (2.6)
8.
Screw the filter housing (2.6) with
the filter housing (7.0) from below
into the filter housing mount and
tighten it by turning it
counterclockwise with an open-jaw
wrench of wrench size 24 mm.
9.
Remove and clean the suction
screen (2.42) according to the
description on page 39 in chapter
"Cleaning/replacing the suction
strainer".
10. Switch on the unit and check for
any leaks.
11. The filter element change is now
complete.