Performing Maintenance
OFX
en(us)
Page 37 / 52
BeWa OFX 3796731 en-us 2014-03-31.doc
2014-03-31
Performing Maintenance
WARNING
Operating pressure
Danger of bodily injury
►
Pull power plug before performing any work.
Changing the filter element
Proceed as follows to replace the filter element:
1.
Turn off the filtration unit using the
operating switch (6.1) and pull out
the power plug.
Unscrew the pressure hose (4.0)
from the coupling or remove it from
the tank.
2.
Unscrew the filter housing (2.6) by
turning it clockwise using a open-
jaw wrench of wrench size 24 mm.
In the process, the fluid
remaining in the top part of the
filtration unit drains out over the
filter element mount.
Ensure that there is always ~ 1 liter
of fluid in the filter housing (2.6).
3.
Remove the used filter element
(7.0) and dispose of it in an
environmentally friendly manner in