8.4.1 Removing/mounting the push-in protective screen
No tools are required.
Fig. 30:
Removing/mounting the push-in strainer
100
Suction hose with quick coupling
700
Quick coupling on the filter unit
701
Seal ring for quick coupling
710
Protective screen, 300 µm
For disassembly, proceed as follows:
1.
Switch off the filter unit and remove the lance from the
container and/or close the shut-off device in order to
prevent any subsequent flow of the medium.
2.
Disassemble the suction hose. For details, see
ing/installing the quick coupling [
.
3.
Now remove the seal ring
(701)
and then the protective
screen
(710)
. In order to do this, insert your finger into
the opening and pull out the seal ring and then the pro-
tective screen with your finger.
O
Disassembly of the protective screen is complete.