6.
If the required filling quantity is reached, switch the filter
unit off at the main switch.
7.
Release the pressure hose at the quick coupling, see
Removing/installing the quick coupling [
.
8.
Empty the contents of the pressure hose into the oil
tank/container.
9.
Empty the contents of the suction hose into the oil tank/
container.
10.
Secure the pressure hose at the quick coupling, see
moving/installing the quick coupling [
.
11.
Secure the cable and, if required, the hoses to the filter
unit, see
.
O
Recirculation is complete.