HNS 526
25
Version: 06.10.2014
HYDAC
ELECTRONIC
GMBH
Part No.: 669869
E
11 Technical details
Input data
Operational scanning range
280;
480;
1600;
4000;
6400
Blind zone
0 .. 30;
0 .. 85;
0 ..200;
0 .. 350;
0 .. 600
Maximum scanning range
350;
600;
2000;
5000;
8000
Angle of beam
See point 7.1. (Recording ranges)
Resolution
≤
0.18 mm
Output data
Accuracy
≤
± 1 % of the current measured value
Repeatability
± 0.15 % of the current measured value
Analogue output (optional)
Signal
(short-circuit resistant)
selectable:
4 .. 20 mA
R
Lmax
.= 100
Ω
(U
B
≤
20 V)
R
Lmax
.= 500
Ω
(U
B
> 20 V)
0 .. 10 V
R
Lmin
.= 100 k
Ω
(U
B
≥
20 V)
Switching outputs
Type
PNP transistor output (short-circuit resistant)
Switching current
max. 200 mA per switching output
Switching direction
N/O or N/C, adjustable
Switch cycles
>
100 million
Reaction time
32; 64; 92; 172; 240 ms
Ambient conditions
Operating temperature
-25°C .. +70°C
Storage temperature
-40°C .. +85°C
mark
DIN EN 60947-5-2
DIN EN 60947-5-7
Vibration resistance to
DIN EN 60068-2-6
(5 .. 2000 Hz)
≤
2 g
Shock resistance to
DIN EN 60068-2-27 (11 ms)
≤
30 g
Protection class to EN 60529
IP 67
Other data
Supply voltage
9 .. 30 V DC without analogue output
20 .. 30 V DC with analogue output
Time delay before availability < 300 ms
Residual ripple
± 10%
Current consumption
≤
80 mA
Electrical connection
M12x1, 4 pole
Housing Brass,
nickel-plated;
Ultrasonic converter with PEEK film
Setting elements
2 buttons
Display elements
3-digit, LED-display, 2 three-colour LEDs
Weight
150; 150; 150; 210; 270 g
Note:
Reverse polarity protection of the supply voltage and short circuit protection are provided.