FluidAqua Mobil - FAM 10
Troubleshooting
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 44 / 72
BEWA FAM10 3549460a en-us 2011-05-05.doc
2011-05-05
Level switch 01/02(02/03)
Step
Description
Malfunction:
Level switch 01/02(02/03)
1.
Switch off the FAM at the main switch.
2
Disconnect plug at level switch and remove level switch.
3.
Manually check the functioning of the switching points
->a. Switching points are available
-> proceed to Step 5.
4.
->b. Switching points not available
-> proceed to Step 6.
5.
Inspect the plug and the cable to and in
the control cabinet for the PLC.
Functioning?
-> proceed to Step 7.
6.
Replace level switch
->a. Function available
-> proceed to Step 8.
7.
->b. Function not available
-> proceed to Step 9.
8.
The PLC is defective.
9.
Replace the damaged parts