![Hydac FCC-CM 5/15 Operating And Maintenance Instructions Manual Download Page 53](http://html.mh-extra.com/html/hydac/fcc-cm-5-15/fcc-cm-5-15_operating-and-maintenance-instructions-manual_2191270053.webp)
Technical Data
FCC-CM
en(us)
Page 53 / 60
BEWA FCC-CM 3648206 en-us 2016-07-08.docx
2016-07-08
Technical Data
FCC-CM 5/4
FCC-CM 5/15
Tank volume
≈
70 liters
≈
70 liters
Operating pressure, maximum 3.5 bar
3.5 bar
Maximum flow rate
4 l/min
15 l/min
Permissible viscosity range
15 … 200 mm²/s
15 … 200 mm²/s
Permitted fluid temperature
range
0 … 80°C
0 to 80°C
Permitted
ambient temperature range
0 to 40°C
0 … 40°C
Permitted
storage temperature range
0 … 50°C
0 … 50°C
Weight when empty
≈
63 kg
≈
63 kg
Filtration rating
2 μm (absolute)
2 μm (absolute)
Contamination retention ca-
pacity:
(when using filter element
N5DM002)
200 g ISO MTD
200 g ISO MTD