Selecting operating modes
FCC-CM
en(us)
Page 27 / 60
BEWA FCC-CM 3648206 en-us 2016-07-08.docx
2016-07-08
Filling the unit
To fill the unit, proceed as follows:
1. Set both ball valves to the position shown.
2. Using the lance, put the suction hose into the appropriate reservoir with
fresh oil without tension or twist, and secure the suction hose against
falling out or floating.
3. Insert the power plug into a suitable power outlet. Make sure that the
voltage is correct.
4. Switch on the unit at the main switch.
5. Monitor the level in the unit during filling using the filling level display at
the back of the tank.
6. Switch off the unit at the main switch once it has reached the "max."
mark.
7. Take the suction hose out of the tank and wind it at the unit.
8. Pull the plug out of the socket and wind the power chord at the unit.
9. The unit is filled and is ready for further tasks.