FluidAqua Mobil - FAM 10
FAM Set-up and Connection
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 34 / 72
BEWA FAM10 3102456f en-us 2012-03-13.doc
2012-03-13
Filling up the rotary vane vacuum pump
Remove the safety screw for the plug at the
level switch (1).
Remove the plug (2) for the level switch.
Unscrew the level switch (3) from the
vacuum pump.
Fill up with vacuum pump oil VE101 through
the filling nozzle (4).
Check the oil level through the inspection
glass (5).
Fill up the vacuum pump oil no higher than
the MAX marking.
We recommend filling up to a level between
the MIN and MAX markings.
The suction strainer is re-mounted in
reverse order.
1
2
3
4
5