Description

The FluidAqua Mobil FAM 

25/45/60/75/95 series operates 

according to the principle of vacuum 

dewatering to separate free and 

dissolved water as well as free and 

dissolved gases from hydraulic and 

lubrication fluids. 

By using HYDAC bypass 

filter technology, with its high 

contamination retention capacity  

and separation performance, the 

 

unit achieves a very high level of  

cost effectiveness. 

All units have an AquaSensor AS 

1000 to continuously monitor the 

water content and to control the 

unit. A CS 1000 particle sensor 

for simultaneous monitoring of the 

solid particle contamination can be 

integrated optionally. 
To increase the dewatering capacity, 

a heater can be integrated optionally 

for highly viscous fluids or for low fluid 

temperatures. 

The Siemens S7 series 

programmable logic controller (PLC) 

used in combination with a Siemens 

touch control panel guarantees simple 

and reliable handling in numerous 

local languages.

Advantages

Extremely low residual water levels, 

gas levels and particle contamination 

in the operating fluids make for:

 

z

Longer oil change intervals

 

z

Improved component service life

 

z

Greater machine availability

 

z

Reduction in the life cycle cost 

(LCC)

Technical specifications

FAM 25

FAM 45

FAM 60

FAM 75

FAM 95

Flow rates at 50 Hz

≈ 25 l/min

≈ 45 l/min

≈ 60 l/min

≈ 75 l/min

≈ 95 l/min

Flow rates at 60 Hz

≈ 30 l/min

≈ 54 l/min

≈ 72 l/min

≈ 90 l/min

≈ 114 l/min

Permitted fluids**

Fluids compatible with NBR seals: 

z

  Mineral oils to DIN 51524 

z

  Gear oils to DIN 51517, 51524

Operating fluids compatible with FKM (FPM,Viton

®

) seals

z

  Synthetic esters (HEES) DIN 51524/2

 

z

  Vegetable oils (HETG, HTG) 

 

z

  HFD fluids (not for pure phosphate ester which require 

 

  EPDM seals).

Sealing material

see model code

Filter size of fine filter

OLF-10

2600

MRF 3/11/40

Filter elements of fine filter 

xxx= Filtration rating

N10DMxxx

2600RxxxBN4HC/-KB (-V-KB) 

N40FMxxx

Clogging indicator

VM 2 C.0

VM 2 C.0

VM 2 C.0

VM 2 C.0

VM 2 C.0

Pump type, vacuum pump

Rotary vane  

vacuum pump

Rotary vane vacuum pump or 

Water ring vacuum pump

Pump type, others

Gear pumps

Operating pressure

max. 6 bar

Permitted pressure at suction 

port (without suction hose)

-0.2 to 1 bar

Permitted pressure at outlet  

(without return hose) **

0 to 3.5 bar

Operation viscosity range**

15 ... 350 mm²/sec (without built-in heater)

 

15 ... 550 mm²/sec (with built-in heater)

Fluid temperature range **

10 ... 80°C

Ambient temperature **

10 ... 40°C

Storage temperature range **

10 to 50°C

Relative humidity (ambient) **

Max. 90%, non-condensing

Electrical  

power consumption (50 Hz)*

Without heater

≈ 3.5 kW

≈ 4.5 kW

≈ 5.9 kW

≈ 7.5 kW

≈ 7.5 kW

With heater

≈ 10.5 kW

≈ 13.5 kW

≈ 19.5 kW

≈ 25.5 kW

≈ 25.5 kW

Heating output (optional)

≈ 6.75 kW

≈ 9 kW

≈ 13.5 kW

≈ 18 kW

≈ 18 kW

Protection class

IP 54

IP 55

IP 55

IP 55

IP 55

Length of electric cable / plug 

10 m / CEE (depending on the nominal voltage, see model code)

Hoses, length

5 m (mobile FAMs only)

Material of hoses 

see model code

Connection, inlet/outlet

see table "Connection summary"

Weight when empty

 ≈ 410 kg

 ≈ 430 kg

 ≈ 550 kg

 ≈ 590 kg

 ≈ 620 kg

Achievable  

residual water content

< 100 ppm – hydraulic and heavy oils 

< 50 ppm – turbine oils (ISO VG 32/46)

 

< 10 ppm – transformer oils ***

*  Maximum specifications given, depends on equipment

 

**  For other fluids, viscosities or temperature ranges, please contact us.

 

*** Units not suitable for "Online" and "Onload" operation (transformer in operation and connected to grid).

Polígono Industrial O Rebullón s/n. 36416 - Mos - España - [email protected]

Servicio de Att. al Cliente

+34 986 288118

Polígono Industrial O Rebullón s/n. 36416 - Mos - España - [email protected]

Servicio de Att. al Cliente

+34 986 288118

Polígono Industrial O Rebullón s/n. 36416 - Mos - España - [email protected]

Servicio de Att. al Cliente

+34 986 288118

Polígono Industrial O Rebullón s/n. 36416 - Mos - España - [email protected]

Servicio de Att. al Cliente

+34 986 288118

Summary of Contents for FluidAqua Mobil FAM 25 Series

Page 1: ... phosphate ester which require EPDM seals Sealing material see model code Filter size of fine filter OLF 10 2600 MRF 3 11 40 Filter elements of fine filter xxx Filtration rating N10DMxxx 2600RxxxBN4HC KB V KB N40FMxxx Clogging indicator VM 2 C 0 VM 2 C 0 VM 2 C 0 VM 2 C 0 VM 2 C 0 Pump type vacuum pump Rotary vane vacuum pump Rotary vane vacuum pump or Water ring vacuum pump Pump type others Gear ...

Page 2: ...0 75 95 only Vacuum pump type R rotary vane vacuum pump W water ring vacuum pump for FAM 60 75 95 only WA water ring vacuum pump with automatic water supply for FAM 60 75 95 only Heater H Heater appropriate for the size see technical data for available voltages see following pages Z without heater Control concept C1 Comfort control panel language de en fr es pt it nl da fi sv C2 Comfort control pa...

Page 3: ...ring see accessories Heater option By using the integrated heater the dewatering capacity can be increased particularly in the case of high viscosity fluids or low fluid temperatures If the temperature of the operating fluid is raised by 10 C then the dewatering capacity increases by up to 50 The ideal temperature for dewatering is roughly 50 to 60 C In general for operating viscosities between 35...

Page 4: ...nce on the dewatering performance The information can thus only serve as a general reference Dewatering rate Water content Fluid temperature Detergent additives Flow rate of the FAM For dimensioning and project planning please use the FAM checklist doc no 10000495854 1 Suction filter 16 Vacuum pump 2 AquaSensor AS 1000 17 Oil mist separator 3 Filling pump 18 Vacuum suction nozzle for the oil mist ...

Page 5: ...rm E Connection Form N to ISO 8434 4 Series L corresponds to ISO 12151 Form SWS Series L Items 1 to 4 are supplied with the stationary FAM Items 5 to 8 are supplied with the mobile FAM in addition to the connection hoses Item FAM 25 FAM 45 FAM 60 FAM 75 FAM 95 1 FAM inlet connector 42L M52x2 male thread 42L M52x2 male thread 42L M52x2 male thread 42L M52x2 male thread 42L M52x2 male thread 2 Adapt...

Page 6: ...summary Required working area Stationary option Measurements FAM 60 75 95 1 2 1780 980 1960 1895 2245 530 785 1 2 850 1940 1830 1800 800 800 800 800 Inlet see table Connection summary Outlet see table Connection summary Required working area Stationary option Polígono Industrial O Rebullón s n 36416 Mos España rodavigo rodavigo com Servicio de Att al Cliente 34 986 288118 Polígono Industrial O Reb...

Page 7: ... required Part number Description Filtration rating Seal 1263071 1263784 2600R003BN4HC KB V KB 3 µm NBR FKM 1263072 1263785 2600R005BN4HC KB V KB 5 µm NBR FKM 1263073 1263786 2600R010BN4HC KB V KB 10 µm NBR FKM 1263074 1263787 2600R020BN4HC KB V KB 20 µm NBR FKM MRF 3 11 40 11 filter elements of the type N40MRxxx PES1F are required Part number Designation Filtration rating Seal 3509897 N40FM P001 ...

Page 8: ...897 509 01 Fax 49 0 6897 509 846 Internet www hydac com E mail filtersystems hydac com Accessories Cover panel package 2 x side sections 1 x rear cover FAM 25 45 Part number Description 3334212 Cover panel FAM 25 45 FAM 60 75 95 Part number Description 3334177 Cover panel FAM 60 75 95 Retrofit kit Ethernet connection for web server For FAM with SIEMENS S7 1200 controller PLC program version V1 56 ...

Reviews: