8.
Errors and troubleshooting
Error
Cause(s)
Remedy
The pump is pumping in the
wrong direction
Check the rotational
direction of the motor and,
if necessary, reverse the
phases.
Shut-off device outside of the
CSM in the intake or pressure
line is closed.
Open shut-off device.
Suction strainer in suction line
of gear pump is dirty.
Clean the suction strainer
No flow
The driver between the motor
and the pump is loose or
defective
Check the driver and, if
necessary, replace it.
No function
No electrical connection
Check the electrical
connection: plug, cable and
socket
For CS1000 error messages, refer to the corresponding chapter in your CS1000
operating and maintenance manual.
9.
Spare parts list
Item
Part no.
Pc. Description
Material
-
3135672
3
Swivel foot
80
278475
1
Suction strainer, 400 µm
90
601981
1
O-ring for suction strainer
FPM
140.10 *
1
Gear pump
140.30 6032344
1
Pump carrier
140.40 6007191
1
Link block
140.50 6032343
1
Coupling sleeve
140.70 3212520
1
Electrical motor 230/400V 50/60 Hz
3ph, 0.18 kW
140.70 3212652
1
Electrical motor 400/690V 50/60 Hz
3ph, 0.18 kW
-
*
1
ContaminationSensor CS 1000
-
6043041
1
Socket plug M12x1, 8-pin with 2 m line
-
6043044
1
Socket plug M12x1, 8-pin with 5 m line
-
6043689
1
Extension line 5 m,
plug socket M12x1, 8-pin / plug M12x1,
8-pin
-
6047931
1
Connecting socket, M12x1, 8-pin
-
*
1
AquaSensor AS 1000
Summary of Contents for CSM 1000 Series
Page 34: ...Notes ...
Page 35: ...Notes ...