8.4 Mode M4: Filter to establish contamination levels continuously
Application:
Control of stationary offline filtration unit
Active data outputs: Display & RS485 & analog output & switching output
Purpose:
Establish reservoir cleanliness between min/max levels
Function:
Control of a filter unit, continuous measurement of solid contamination, if pre-
programmed min/max levels are exceeded, the pump is switched on/off to keep
cleanliness within range
8.5 Mode M5: "SINGLE" measurement
Application: Stand-alone
sensor
Active data outputs: Display & RS485 & analog output
Purpose:
Perform a single measurement only
Function:
Single measurement of solid contamination, without any switching functions
When Single mode is selected in the Power Up menu, the following appears in the display when
switching to the Measuring menu or after switching the CS on:
START?
Confirm by actuating the
o.k.
key. The CS begins with a
single measurement sequence. Actuating the
Esc
key
causes the sensor to go back one level in the menu structure.