Technical Data
OXiStop OXS
en
Page 101 / 108
MoWa OXS 3992763e en-us 2018-08-10.docx
2018-08-10
Technical Data
The unit has the following technical data:
Hydraulic data
Differential
Volume
Reservoir
volume
OXS 30
≤ 30 l
110 l
OXS 45
≤ 45 l
135 l
OXS 70
≤ 70 l
185 l
Permitted operating fluids
Mineral oils acc. to DIN 51524
Typical gas removal rate
4 l/h
Permissible viscosity range
15 … 300 mm/s²
15 … 200 mm/s² with OLFCM
Maximum fluid flow rate
(depending on return filter NFxxx)
≤125 l/min @ NF 160
≤125 l/min @ NF 240
≤125 l/min @ NF 280
≤450 l/min @ NF 330
≤450 l/min @ NF 500
≤450 l/min @ NF 750
≈ 900 l/min o return line filter
Permitted fluid temperature range
10 - 80°C
Electrical data
Power supply, frequency
See name plate on the electric
motors
Wattage
See name plate on the electric
motors
Protection class to DIN 40050
See name plate on the electric
motors