Performing maintenance
Suction strainer cleaning interval
The filtration unit is equipped with various suction screens depending on its
design.
The suction strainer (5a) has a much larger absorption capacity at a mesh
width of 300 µm than the suction screen (5b) with a mesh width of 100 µm.
This results in very different cleaning intervals for the different versions.
Item
Mesh size
Maintenance interval
5a
-> 300 µm
- every 25 operating hours*
- at least monthly*
- at every filter change*
5b
-> 100 µm
- every 10 operating hours*
- at least weekly*
- at every filter change*
*) For heavily contaminated fluid, the maintenance intervals shorten.
If the effectiveness of the pump falls or if the pump's noise
levels increase, then check / clean the suction strainer.
OF7S / OF7K
en(us)
Page 47 / 68
BeWa OF7 3430048e en-us 2016-04-28.doc