Performing maintenance
Checking / Replacing hoses
Replace the hydraulic hoses every six years at the latest.
The six operating years include two years storage duration for normal
requirements in accordance with the rules of the Employers Liability
Insurance Association BGR 237 for normal requirements.
Maintaining membrane pump
The membrane pump is subject to wear. If the pump line eases off, perform
maintenance according to the manufacturer's information. For details, view
the operation and installation instructions of the pump manufacturer.
Remove the screw-in supports at the inlet and outlet of the membrane pump
with a maximum torque of 5 Nm.
CTM-SC 3xxx series
en(us)
Page 33 / 56
BeWa CTM-SC 4165698b en-us 2017-05-10.docx
2017-05-10
Summary of Contents for CTM-SC 3 Series