HLT 2550-L2 CANopen
13
Edition: 2017-08-08
HYDAC
ELECTRONIC
GMBH
Part No.: 669955
E
7 Technical Data
Note:
Reverse polarity protection of the supply voltage and excess voltage protection and short
circuit protection are provided.
FS
(
F
ull
S
cale) = relative to the complete measuring range
1)
Other measuring ranges on request.
2)
with mounted female connector having the corresponding protection class
Input data
Measuring ranges
1)
30 .. 3000 mm in steps of 50 mm
Type
Profile, with magnetic guidance at the top
Material
Measuring body: aluminium
Output data
Output signal
CANopen
Resolution 0.05
mm
Non linearity
≤
± 0.01 % FS,
≥
0.06 mm
Hysteresis
≤
± 0.1 mm
Repeatability
≤
± 0.005 % FS,
≥
0.05 mm
Temperature coefficient
≤
± 0.01 % FS / °C typ.
Sampling rate
Depends on length : :
0.5 ms
(measuring range
≤
1200 mm)
1.0 ms
(measuring range
≤
2400 mm)
2.0 ms
(measuring range
≤
3000 mm)
Ambient conditions
Operation temperature range
-20 .. +75 °C, optional -40 .. +75 °C
Storage temperature range
-30 .. +85 °C
- mark
EN 61000-6-1 / 2 / 3 / 4
Vibration resistance acc. to
DIN EN 60068-2-6 at 50 .. 2000 Hz
≤
10 g
Schock resistance acc. to
DIN EN 60068-2-27 (11 ms / half sine )
≤
100 g
Protection class acc. to DIN EN 60529
2)
IP 67
Installation position
No restrictions
Protocol data for CANopen
Communication Profile
CiA DS 301 V4.2
NMT-Services
CiA DSP 302 V4.1
Layer Setting Services and Protocol
CiA DSP 305 V2.2
Encoder Device Profile
CiA DS 406 V3.2
Baudrate
10 kbit/s . 1 Mbit/s acc. to DS305 V2.2
Transmission services
- PDO
- Transfer
measured value as 32 bit and float
synchronous, asynchronous, cyclical
Node Id/Baudrate
Adjustable via LSS
Other data
Supply voltage
24 V DC ± 20 %
Residual ripple of supply voltage
≤
250 mVpp
Current consumption without output
˂
100 mA
Weight
Depends on length :
30 mm:
̴
300 g
3000 mm:
̴
3900 g