7 Technical Data
7.1 HLT 2100-R1 (Rod Version, partly integrated)
Input data
Measuring ranges
50 .. 4000 mm
Housing Aluminium
Hydraulic tube
Stainless steel
Pressure resistance
450 bar
Peak pressure
750 bar
Output data
Signal output
Current:
4 .. 20 mA or 20 .. 4 mA
Voltage:
0 .. 10 V or 10 .. 0 V
Resolution
16 Bit;
≥
0.005 mm
Ohmic resistance to GND
Current:
200 .. 500
Ω
Voltage: >
2
k
Ω
Accuracy
≤
± 0.5 % FS typ.
Non linearity
± 0.1 mm
to 1,500 mm
± 0.15 mm
> 1,500 mm
Hysteresis
≤
± 0.1 % FS
Repeatability
≤
0.005 mm -
≤
0.05 mm (depends on length)
Temperature coefficient
≤
± 0.004 % FS / °C
Sampling rate
2 ms
Installation position and travel speed
No orientation restrictions
Ambient conditions
Operating temperature range
0 .. +70 °C
Storage temperature range
-30 .. +85 °C, dry
Relative humidity
98 %, non-condensing
- mark
EN 61000-6-1 / 2 / 3 / 4
Vibration resistance per
DIN EN 60068-2-6 at 50 .. 2000 Hz
≤
10 g
Shock resistance according to
DIN EN 60068-2-27
≤
100 g / 11 ms / half sine
Housing /
Protection class to IEC 60529
1)
Aluminium /
IP 65
Other data
Electrical connection
- Jacketed cable, length 1 m
1)
- Male M16, 6 pole
- Male M16, 8 pole
Supply voltage
24 V DC
±
10 %
Residual ripple of supply voltage
≤
250 mV
PP
Current consumption without output
< 250 mA
Weight
Depends on length
Note:
Reverse polarity protection of the supply voltage and excess voltage protection and short
circuit protection are provided.
FS
(
F
ull
S
cale) = relative to the full measuring range
1)
further variants on request