18
HLT 2100 / HLT 2500 SSI
Edition: 2017-08-31
HYDAC ELECTRONIC GMBH
Part No.: 669999
E
7.3 HLT 2500 – F1
Input data
Measuring ranges
50 .. 4000 mm
Design
Flat profile, without magnetic guidance
Housing
Measuring body: aluminium
Output data
Output signal
SSI
Resolution 0.05
mm
1)
Non linearity
± 0.15 mm (measuring range
≤
1500 mm)
± 0.2 mm
(measuring range > 1500 mm)
Hysteresis
≤
0.1 mm
Repeatability
≤
0.05 mm -
≤
0.5 mm (depends on length)
Temperature coefficient
≤
± 0.0015 % FS / °C
Sampling rate
Depending on length
≤
1 m 1.0 ms
≤
2 m 1.5 ms
≤
3 m 2.0 ms
>
3
m
2.5
ms
Environmental conditions
Operating temperature range
0 .. +70 °C, optionally – 20 ..+ 70 °C
Storage temperature range
-30 .. +85°C
- mark
EN 61000-6-1 / 2 / 3 / 4
Vibration resistance acc. to
DIN EN 60068-2-6 at 50 .. 2000 Hz
≤
10 g
Shock resistance acc. to
DIN EN 60068-2-27 (11 ms / half sine)
≤
100 g
Protection class acc. to DIN EN 60529
2)
IP 65
Installation No
restrictions
Relevant data for SSI
SSI clock input
Opto coupler
SSI data output
RS-422, 2 wires
SSI clock frequency
95 .. 1000 kHz
SSI mono time, typical
20 µs
Other data
Supply voltage
24 V DC - 20.. + 10 %
Residual ripple of supply voltage
≤
250 mV
PP
Current consumption without output
< 250 mA
Weight
Depending on length:
50 mm:
̴
550 g
4000
mm:
̴
4000 g
Note:
Reverse polarity protection of the supply voltage and excess voltage protection and short circuit
protection are provided.
FS
(
F
ull
S
cale) = relative to complete measuring range
1)
further variants on request
2)
with mounted mating connector in corresponding protection class
Summary of Contents for HLT 2100-R1