Input data
HDA 4400
HDA 4700
Measuring
Ranges
bar -1..5 -1..9 6 16 40 60 100 160 250 400 600 1000
Overload
ranges
bar 15 20 15 32 80 120 200 320 500 800 900
1)
1600
Burst pressure
bar 100 100 100 200 200 300 500 800 1000 2000 2000 3000
Measuring
Ranges
psi 100 150 200 300 500 600 700 750
1000
psi 1500 2000 3000 5000 6000 9000 10000 15000
Overload
ranges
psi 290
290 460
1160 1160 1160 1740 1740 2900
psi
2900
4600
7250
11600 11600 14500
14500
23200
Burst
pressure
psi 1450 1450 2900 2900 2900 2900 4350 4350
7250
psi
7250
11600 14500
29000 29000 29000
29000
43500
Mechanical connection
see model code / dimensions
Tightening torque
See dimensions
Standard
Flush membrane
Stainless steel
1.4435; 1.4301
1.4435; 1.4301
Seal FPM
FPM
O-ring
FPM
Pressure transfer fluid
Silicon-free oil
Output data
Output signal
4 .. 20 mA (2-conductor), R
Lmax.
= (U
B
– 12 V) / 20 mA [k
Ω
]
Curve deviation at max. setting to DIN
16086 (accuracy class)
Typ.
Max.
≤
±
0.5 % FS
≤
±
1.0 % FS
≤
±
0.25 % FS
≤
±
0.5 % FS
Curve deviation at min. setting
Typ.
max.
≤
±
0.25 % FS
≤
±
0.5 % FS
≤
±
0.15 % FS
≤
±
0.25 % FS
Temperature compensation
Typ.
≤
±
0.015 % / °C
≤
±
0.008 % / °C
Zero point
max.
≤
±
0.025 % / °C
≤
±
0.015 % / °C
Temperature compensation
Typ.
≤
±
0.015 % / °C
≤
±
0.008 % / °C
Over range
max.
≤
±
0.025 % / °C
≤
±
0.015 % / °C
Non-linearity at max. setting to
DIN 16086
max.
≤
±
0.3% FS
≤
±
0.3 % FS
Hysteresis max.
≤
±
0.4 % FS
≤
±
0.1 % FS
Repeatability
≤
±
0.1 % FS
≤
±
0.05 % FS
Rise time
≤
1.5 ms
≤
1.5 ms
Long term drift
Typ.
≤
±
0.3 % FS / year
≤
±
0.1 % FS / year
Ambient conditions
Compensated temperature range
-20 .. + 85°C
Operating temperature range
2)
-20 .. + 60 °C
-40 .. + 60 °C / -20 .. + 60 °C
Storage temperature range
-40 .. +100 °C
Medium temperature range
2)
-40 .. + 60 °C / -20 .. + 60 °C
- Marked
EN
61000-6-1/2/3/4
IEC 60079-0/11/26/36
Vibration resistance to
IEC 68-2-6 at 10 ..500Hz
≤
20 g
Protection class to IEC 60529
IP 65
(connector EN175301-803 (DIN 43650) and Binder 714 M18)
IP 67 (M12x1 male connector, for use with IP 67 female connector)
Relevant data for Ex
Application
Ex ia, ic
Ex nA, ta, tb, tc
Supply voltage
U
i
= 12 .. 28V
12 .. 28 V
Max. input current
Ii = 100 mA
Maximum input power
P
i
= 1W
max. power consumption
≤
1W
Capacity of transmitter
C
i
≤
22 nF
Inductance of transmitter
Li = 0 mH
Insulation voltage
50 V AC with integrated overvoltage protection EN 61000-6-2 or
500 V AC, depending on the model (see model code)
Other data
Reverse polarity protection of the supply
voltage, short circuit protection
excess voltage
Standard
Residual ripple supply voltage
≤
5 %
Service life
> 10 million cycles
Weight
ca. 150 g (Standard)
ca. 180 g (flush mount version)
Note: FS (
F
ull
S
cale) = relative to the full measuring range
B.F.S.L
=
B
est
F
it
S
traight
L
ine
1)
Standard overload range 1000 bar, flush mount version overload range 900 bar
2)
-25°C with FPM seal, -40°C on request