HYCON HRS400 Ring Saw
HYCON A/S • Juelstrupparken 11 • DK-9530 Støvring • Tel +45 9647 5200
14
Replacement/Adjustment of Blade
Loosening:
Loosen the tightening knob completely by turning it counter
clockwise, thereby loosening the blade from the drive wheel.
Tightening:
To adjust the blade firmly against the drive wheel, turn both
tightening knobs clockwise alternately so that the built-in
compression springs are pressed together. Make sure that the
distance between blade and water blade is the same both at
the left and the right side.
Adjustment of Support Rollers
Loosening:
Use a ring spanner size 13 mm to loosen the hexagon nuts
and then retighten them slightly. Turn the adjustment screw
approx. 8-9 turns counter clockwise. This will lift the support
roller approx. 2 mm from the blade.
Tightening:
Adjust the support roller down against the blade by loosening
the hexagon nuts just slightly and then turning the adjustment
screw clockwise. Do under no circumstances press the support
roller too hard against the blade. You must be able to turn the
blade by hand. Now tighten the hexagon nuts completely.
If the guide rollers cannot be turned
completely back into bottom position, the
cause could be deposit of concrete
dust/slurry on the back side. Dismount the
rollers and clean thoroughly.
If the support rollers cannot be turned
completely back into bottom position, the
cause could be deposit of concrete
dust/slurry on the back side. Dismount the
rollers and clean thoroughly.