12. Troubleshooting
Problem
Likely Fault(s)
Solution
Water and steam spitting from
the tap
This is normal but temperature
can be adjusted if desired. Water
temperature is set to 100°C.
Turn temperature down to 98°C
on PC board. See Section 6
Tank not heating and no LED
lights
Thermal cut out has tripped
Reset using cut out button. See
Section 6
Tank not heating and red light
flashing
Software error
Contact Hyco
Water dripping from the tap
Tap fault
Contact Hyco
Reduced flow from the cold side
of the tap when using Crossover
valve
Drinking water filter needs
changing
Replace drinking water filter
cartridge. See Section 8
Low flow from the boiling side
of the tap
Scale filter needs changing
Replace scale filter cartridge. See
Section 8
Low flow from the boiling side
of the tap
Scale build up in tank
Descale tank. See section 10
Low flow from the tap
Aerator needs cleaning
Unscrew, remove and clean
aerator
Dispensed water is too hot
Water temperature is set to
100°C
Turn temperature down to 98°C
on PC board. See Section 6
11. Specification
Supply
230V ~ 50Hz
Power 3/ 6L model
1.55/ 2.84 kW
Tank capacity 3/ 6L model
3/ 6 litres
Max water pressure
0.42 MPa (4.2 bar)*
Min water pressure
0.1MPa (1 bar)
Max tank pressure
0.6 MPa (6 bar)
Ambient operating temperature
5 – 35°C
Approvals
CE
* If pressure is above 0.42 MPa (4.2 bar) a pressure reducing valve is required.
26
Summary of Contents for Zen Life LIFE3L
Page 7: ...Diagram 1 Installation without Crossover Valve 7...
Page 9: ...Diagram 2 9...
Page 15: ...Diagram 4 Installation with Crossover Valve 15...
Page 17: ...Diagram 6 Diagram 7 17...
Page 23: ...3L Model PC Board Diagram 8 6L Model PC Board Diagram 9 23...
Page 29: ......