Select a suitable location for the scale filter housing ensuring easy access for future
maintenance. The arrow represents the water flow direction and must be followed.
•
Depending on installation you may need to remove the filter head from bracket
and rotate 180° to ensure flow arrow is followed.
•
To do so first remove filter cartridge. Now grip bracket in one hand and the top
t-section with the other, turn 90° anticlockwise to release.
•
Rotate 180° and reinsert t-section, turning 90° in whichever direction is required
depending on installation, to secure.
•
Do not locate the filter above an electrical socket or other electrical device.
Step 5 - Connect Mains Cold and Scale Filter
•
The supplied scale filter is suitable for up to 300 ppm. You may need to upgrade to
a higher capacity filter in more aggressive water areas.
Note these are larger in
size so ensure sufficient space is available.
•
Isolate mains supply and make a connection using the 1/2” BSP to 15 mm brass
fitting supplied. We recommend fitting a service valve (not supplied) close by to aid
any future maintenance.
•
Connect ½ “ female to 3/8 “ PF (push fit) connector to the brass fitting.
•
Ensure all tubing is pushed fully into PF connectors and that locking collars
are used to prevent inadvertent removal.