6. Change Temperature Setting and Thermal Cut-out Reset
•
The appliance must first be isolated from the mains power supply by unplugging
but is not necessary to isolate the water supply.
•
Open the boiling side of the tap until water runs cold.
•
The Zen Life is factory set at 100°C. The temperature of dispensed boiling water can
be changed on the tank PCB. Switch between ‘LO’ 98°C or ‘HI’ 100°C.
•
See Diagram 8 and 9 overleaf.
•
For the 3L and 6L models unscrew the 2 crosshead screws that retain the boiling
tank lid.
•
Lift the lid slightly from the back before removing by sliding it forward to free it
from the retaining lug at the front.
•
For the 6L model unscrew the 2 crosshead screws that retain the back section and
remove.
•
To change the temperature locate the temperature setting switch; slide to HI for
100°C / LO for 98°C setting as appropriate.
•
To reset the thermal cut-out locate and press the reset button. For the 3L model
this is on the PC board. For the 6L model it is on the top of the boiling tank.
•
For the 6L model replace the back section and replace two retaining screws.
•
For the 3L and 6L model replace the lid by first lining up the lug at the front before
gently angling the back into place. Replace the two retaining screws.
•
When the lid is secured in place re-connect the electrical supply.
22
Summary of Contents for Zen Life LIFE3L
Page 7: ...Diagram 1 Installation without Crossover Valve 7...
Page 9: ...Diagram 2 9...
Page 15: ...Diagram 4 Installation with Crossover Valve 15...
Page 17: ...Diagram 6 Diagram 7 17...
Page 23: ...3L Model PC Board Diagram 8 6L Model PC Board Diagram 9 23...