These fitting and User Instructions refer to the following models: 

AP25LM   AP50LM   AP75LM   AP100LM

The HYCO Apollo series is a range of white enamelled cistern fed rectangular water storage 

heaters. All HYCO Apollo units can be connected directly to the cold water main and if required, 

can supply more than one outlet without the need for special taps. 

 

WARNING!

-The appliance is not to be used by children or persons with reduced physical, sensory or

mental capabilities, or lack of experience and knowledge, unless they have been given 

supervision or instruction.

-Children should be supervised and not allowed to play with the appliance.

-Maximum water pressure 690kPa  

 

THESE INSTRUCTIONS SHOULD BE CAREFULLY READ AND UNDERSTOOD BEFORE  

INSTALLATION BEGINS. IT WOULD BE DANGEROUS TO PROCEED IF ANY PART IS 

UNCLEAR OR IF THE REQUIREMENTS CANNOT BE FULLY MET. 

PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER AFTER INSTALLATION. 

INSTALLATION

 

WALL MOUNTING (refer to diagram A). 

The unit is designed to be wall mounted and must be fitted at least one metre above the 

highest draw-off point thus ensuring a good flow. It is important that sufficient clear

a

nce is 

allowed to ensure access to the ball valve assembly. 

The wall fixing points will accept 8mm bolts which should not be less than 50mm in length. 

ALWAYS ENSURE THAT THE WALL IS SUFFICIENTLY STRONG TO CARRY THE WEIGHT 

OF THE UNIT WHEN IT IS FULL OF WATER. 

 

PIPEWORK CONNECTIONS (refer to Diagram B).

The installation must conform to all local authority byelaws. The cold water supply and warning 

pipe (overflow) assembly can be connected to either side of the unit. The respective apertures 

are pre-formed in the outer case and these should be used as guides for cutting through the 

cold water tank. A 22mm hole is required for the inlet and a 27mm hole for the 

warning

 pipe. 

An isolating valve must be fitted to the cold water mains supply to allow for servicing. 

FITTING TO THE COLD WATER TANK (refer to Diagram C).

The HYCO Apollo series of water heaters are supplied with all the components that are required 

to comply with the WRC bylaw 30. The arrangement of these should conform to Diagram C. 

The filter and breather assembly is a push snap-fit connection and should be fitted to the lid in 

the aperture provided. 

The warning pipe assembly (overflow) has three components. The threaded elbow (tank 

connector) is inserted through the hole that has been cut, and tightened with the nut and 

sealing washer on the inside of the tank. 

The 90

o

 bend internal “dip tube” is pushed firmly into the connector facing downwards. The 

warning pipe (overflow) screen is located securley into the downwards external connection of 

the connector.

 

The ball valve assembly is fitted as required, adjusting the float to ensure that the water level 

in the tank does not exceed the water level line.

 

NOTE:  after installation, replace lid and secure with the retaining screw supplied.