ELECTRICAL CONNECTION 

The Installation should be carried out by a suitably qualified person in accordance with BS 7671 

(IEE) wiring regulations. 

A double pole isolation switch having a contact separation of greater than 3mm should be fitted 

to allow for servicing. 

IMPORTANT:

 The unit MUST be full of water before switching on the electricity supply. 

The HYCO Apollo water heaters are all fitted with a 3kW heating element. The heating element 

is located at the base of the unit. The heating element incorporates dual thermostats that are 

linked to act as a control thermostat with an over-temperature safety cut-out. The thermostats 

are factory set to 50

o

C for the control thermostat and 70

o

C for the cut-out thermostat. 

The control thermostat should NOT exceed 60

o

C and the 20

o

C differential between the control 

and cut-out thermostat MUST be maintained. 

The supply cable should be securely clamped before replacing the heating unit’s own cover AND 

as it passes through the gland in the element housing cover. 

If during normal service, the cut-out thermostat operates first establish the reason for 

operation. Possibly a wrongly set control thermostat. Switch off the electricity supply before 

removing the element housing cover. Correct the problem and then press the button to reset 

the cut-out thermostat. Replace the heating unit cover and the element housing cover before 

switching on the electricity supply. 

SCHEMATIC WIRING DIAGRAM

OPERATION

The cold water supply to the integral cistern is controlled by the ball valve. when one or more 

hot taps are opened the hot water drawn from the unit is replaced from the contents of the cold 

water cistern that is refilled automatically.

COMMISSIONING 

Before making the electrical connection it is recommended that the unit is filled and checked 

for leaks. Apart from the plumbing connections, the element or drain may have been loosened 

in transit and require tightening, 

SAFETY WARNING 

The unit MUST NOT be used if it is suspected of being frozen. If water caeses to flow switch off 

electricity supply immediatley at the isolating switch. If the unit is to be serviced or drained 

disconnect the electricity supply before commencing the operation.