Installation and Maintenance Manual
24
Description of Functions Available in the Installer Menu
Installer 1
[uC 0]
Set UL Usage Class:
This menu item is used to set the UL usage class, which
must be set by the installer before the operator will function. See page 17, step 2.
Installer 2
[Fd 0]
Load Factory Defaults:
This menu item is used to globally restore all menu
settings back to new machine status. To activate, change the setting 0 to 1 and push the Menu button.
The UL usage class and the hand configuration will need to be set again.
Installer 3
[dg 0]
Set Solo, Master or Slave type:
This menu item is used to configure an operator
as a Master or a Slave operator in Master/Slave paired gate installations.
Installer 4
[Ch 0]
Set AC Charger or Solar:
This menu item only appears on 24 VDC battery
machines only and is set to solar only when there is no AC battery charger.
Installer 5
[Fo 0]
Enable Fire Dept. Open:
This menu item is used to enable the Fire Dept. Open
input. When set to [Fo_1] this input will override vehicle detectors, photo eyes and gate edges to open a
gate. A reset input is required before the gate can be closed.
Installer 6
[oC 0]
Enable Emergency Close:
This menu item is used to enable the Emergency
Close input. When set to [oC_1] this input will, with a constant hold input, override vehicle detectors,
photo eyes and gate edges to close a gate. A reset input is required before the gate can be opened.
Installer 7
[SE 6]
Inherent Sensor sensitivity:
. This menu item is to adjust the sensitivity of the
internal inherent sensor. Available settings are 1-9, with 9 being the least sensitive.
Installer 8
[SS 0]
Inherent Sensor function:
This menu item is only available in UL class 4
operators and allows an option whereby the inherent sensor will only stop the gate.
Installer 9
[LC 0]
Leaf delay Close:
This menu item only appears if the operator is set up as a Master
or a Slave. Available settings are 1-7. Each increment adds ½ second, to a maximum of 3 ½ seconds
time delay, before the operator activates when commanded to close.
Installer 10
[Lo 0]
Leaf delay Open:
This menu item only appears if the operator is set up as a
Master or a Slave. Available settings are 1-7. Each increment adds ½ second, to a maximum of 3 ½
seconds time delay, before the operator activates when commanded to open.
Installer 11
[rt 0]
Maximum run timer:
The maximum run timer has a default setting of 60 seconds.
This menu item allows an optional setting of 300 seconds, if changed to [rt_1].
Installer 12
[EC 0]
PEC (photo eye close) reverse to open:
The default for this menu item is for
non-reversal if the close photo eye is triggered. The optional setting of [EC_1] will cause the gate to
reverse to open for two seconds if triggered while closing.
Installer 13
[PC 0]
Set PEC – NO/NC:
The default for this menu item is for photo eyes with Normally
Open outputs. The optional setting of [PC_1] will require a Normally Closed output. If set for N.C. the
connection is also supervised and any open or short circuit fault will generate a FAL2 alert, which
requires a Stop button reset to re-enable any function if triggered.
Installer 14
[gC 0]
Set Edge input – NO/NC:
The default for this menu item is for edge sensor with
Normally Open outputs. The optional setting of [gC_1] will require a N.C. output.
Summary of Contents for HTG 320-2
Page 16: ...Installation and Maintenance Manual 10 Components of the Barrier Arm Gate Operator ...
Page 19: ...Installation and Maintenance Manual 13 ...
Page 20: ...Installation and Maintenance Manual 14 ...
Page 21: ...Installation and Maintenance Manual 15 ...
Page 25: ...Installation and Maintenance Manual 19 ...
Page 41: ...Installation and Maintenance Manual 35 E95 ...
Page 54: ...Installation and Maintenance Manual 48 ...
Page 55: ...Installation and Maintenance Manual 49 ...
Page 57: ...Installation and Maintenance Manual 51 ...
Page 58: ...Installation and Maintenance Manual 52 Parts Breakout ...
Page 59: ...Installation and Maintenance Manual 53 Parts Breakout ...
Page 60: ...Installation and Maintenance Manual 54 Parts Breakout ...
Page 61: ...Installation and Maintenance Manual 55 Parts Breakout ...
Page 62: ...Installation and Maintenance Manual 56 Parts Breakout ...
Page 63: ...Installation and Maintenance Manual 57 Parts Breakout ...
Page 64: ...Installation and Maintenance Manual 58 Parts Breakout DC Power Supply Battery Pack Components ...