![HWH 600 Series Operator'S Manual Download Page 20](http://html1.mh-extra.com/html/hwh/600-series/600-series_operators-manual_2190645020.webp)
ROOM EXTENSION SYSTEM
ELECTRICAL CONNECTION DIAGRAM
VIEW FROM PUMP END
MP85.474C
13MAY99
SEE GROUNDING
INSTRUCTIONS
6245
A
B
A
B
8 7
1 4
2 5
3 6
3 6
2 5
1 4
8 7
ROOM EXTEND/
RETRACT SWITCH
ROOM ON/PFF
SWITCH
FROM CONTROL
HARNESS
BY O.E.M.
RETRACT - BLACK (4)
PUMP CONTROL - GRAY (1&3)
EXTEND - YELLOW (6)
RETRACT -
BLACK (4)
SWITCHED
BATTERY -
RED (2)
RED
FROM IGNITION -
ORANGE (2)
SWITCHES BY O.E.M.
SEE DETAIL A
(6 PIN FEMALE)
DO NOT REVERSE
WIRE COLORS TO
A & B ON PACKARD
CONNECTORS
RETRACT -
5100
SWITCHED
BATTERY -
6810
EXTEND -
5000
PUMP
CONTROL -
7541
DETAIL A
NO
CONNECTION
NO
CONNECTION
RETRACT SOLENOID
VALVE - ROOM
EXTENSION
EXTEND SOLENOID
VALVE -
GENERATOR
SLIDE
RETRACT
SOLENOID VALVE -
GENERATOR SLIDE
SEE ELECTRICAL
CONNECTION
DIAGRAM GENERATOR
SLIDE SYSTEM FOR
CORRECT
CONNECTION
INFORMATION
GR
GE
RR
RE
VALVE RELEASE
"T" HANDLE
ROOM EXTENSION
MANIFOLD
EXTEND SOLENOID VALVE
ROOM EXTENSION
HWH ROOM
CONTROL
HARNESS
5000
6245
6245
5100
SEE ELECTRICAL
CONNECTION
DIAGRAM ROOM
EXTENSION
PUMP RELAY
6810
8602
NOTE: THE JACK
INTERRUPT IS
ONLY USED IF THE
VEHICLE IS EQUIPPED WITH A
HWH HYDRAULIC LEVELING SYSTEM.