FS+’q’+n+(xL+xH+yL+yH+d1…dk)1……+(xL+xH+yL+yH+d1…dk)n
[Name] Register logo (bitmap image) non volatilization
[Format] ASCII
FS q n (xL xH yL yH d1..dk)1…(xL xH yL yH d1..dk)n
Hex
1C 71h n (xL xH yL yH d1..dk)1…(xL xH yL yH d1..dk)n
Decimal 28 113 n (xL xH yL yH d1..dk)1…(xL xH yL yH d1..dk)n
[Range] 1
≤
n
≤
255
0
≤
xL+xH×256
≤
65535 (0
≤
xL
≤
255, 0
≤
xH
≤
255)
0
≤
yL+yH×256
≤
65535 (0
≤
yL
≤
255, 0
≤
yH
≤
255)
0
≤
d
≤
255
k=(xL+xH×256)×(yL+yH×256)×8,
Capable register : 64kbytes
[Descript.] Register the logo non-volatilization
n : Total unit of N/V logo
xL,xH : Set the horizontal dot in (xL+xH×256)×8
yL,yH : Set the vertical dot in (xL+xH×256)×8
k : Bitmap image of a N/V logo
[Caution]
Register various as much as NV’s capa.
Required to delete all if (it is) registered again.
Renewable registeration / deletion at 100000 cycles,
It’s not recommended frequent registeration / deletion,
due to memory damage
<Register Image >
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
D1
D(x×8-1)×y+1
MSB
Title Rev.
Page
HMK(P)-081,HMC-081 Ver1.0
40
FS+’p’+n+m
[Name]
Printing N/ V logo
[Format]
ASCII
FS
p
n
m
Hex
1C
70h
n
m
Decimal
28
112
n
m
[Range]
1
≤
n
≤
255, 0
≤
m
≤
3
[Initial Value]
n=0
[Descript.]
m : printing the registered N/V in ‘m’ mode
n : indicating the regsitered logo in the ‘n’.
m
Printing
mode
0 Standard
1 Horizontal
extension
2 Vertical
extension
3
Horizontal,vertical extension in the same time
Dy
D(x×8)×y
LSB