background image

2

SERIOUS COMMITMENT

All products of our company carry one year limited warranty

from the date of shipment. If any such product proves defective

during this warranty period we will maintain it for free. Meanwhile

we implement lifetime service. Except otherwise agreed by

contract.

SAFETY REQUIREMENTS

Please read the following safety precautions carefully to avoid

body injury and prevent the product or other relevant subassembly

to damage. In order to avoid possible danger, this product can only

be used within the prescribed scope.

Only qualified technician can carry out maintenance or repair

work.

--To avoid fire and personal injury:

Use Proper Power Cord

Only use the power wire supplied by the product or meet the

specification of this produce.

Connect and Disconnect Correctly

When the test wire is connected to the live terminal, please do

not connect or disconnect the test wire.

Grounding

The product is grounded through the power wire; besides, the

Summary of Contents for HTJY-80S

Page 1: ...nual You can find the changes in the appendix Sorry for the inconvenience If you have further questions welcome to contact with our service department The input output terminals and the test column ma...

Page 2: ...and prevent the product or other relevant subassembly to damage In order to avoid possible danger this product can only be used within the prescribed scope Only qualified technician can carry out main...

Page 3: ...d the instruction manual to acquire information about the ratings Do Not Operate without Covers Do not operate this product when covers or panels removed Use Proper Fuse Only use the fuse with type an...

Page 4: ...Security Terms Warning indicates that death or severe personal injury may result if proper precautions are not taken Caution indicates that property damage may result if proper precautions are not tak...

Page 5: ...d technical indicators 7 Fourth conditions of use 7 fifth Description of chassis and panel parts 8 sixth diagram of operation steps 9 The seventh matters needing attention 16 eighth simple troubleshoo...

Page 6: ...reliable Second the instrument characteristics 1 Instrument adopt large capacity single chip microcomputer control stable and reliable work 2 The instrument is equipped with temperature and humidity i...

Page 7: ...2 The pressure rise rate of 2 0 kV s 2 5 kV s 3 0 kV s 3 5 kV s four gears Error 0 2 kV s 3 The output voltage of 0 80 kV optional 4 Voltage accuracy 2 reading word 2 5 Power distortion rate of 1 6 Th...

Page 8: ...he liquid crystal display 2 The function keys 3 The printer 4 The rate of pressure rise toggle switch 5 The indicator light 6 Oil cup cover 7 Temperature humidity sensor 8 Ground column 9 The power sw...

Page 9: ...steps is now under way 6 Oil cup cover open add or remove oil cup after close the rear can test 7 Temperature humidity sensor to measure temperature of 0 degrees Celsius temperature and relative humi...

Page 10: ...gure 1 page press set button to enter the next level page figure 2 Figure 2 selector page 3 In figure 2 page press the select key to move the cursor GB1986 press the ok button to enter national standa...

Page 11: ...kV incremental 10 kV Choose good after stopping up voltage press keys move the cursor to a cup of a selection press confirm button to enter a cup a selector page figure 4 Figure 4 cups of a selector p...

Page 12: ...f ground wire or no conditions can press any key to skip will not affect the test results 4 In figure 2 page press the select key to move the cursor GB2002 press the ok button to enter national standa...

Page 13: ...Figure 6 a custom Settings page 7 In figure 6 pages press the select key move the cursor to the corresponding option then press the or key parameters can be set Among them Let stand for 15 min the de...

Page 14: ...ter a selection child pages specific see six operation operation steps diagram 3 The related content 7 For this model every cup of up to 6 times parallel determination parameters such as the breakdown...

Page 15: ...e measuring time according to data for the stored data set will not be lost after shutdown If the oil cup sample is more than three the system will be grouped by time records show that the recent thre...

Page 16: ...p and oxide electrode 5 Use after a month in a row electrode should be routine inspection and maintenance Check and adjust the electrode gap make its restore standard A magnifying glass to observe whe...

Page 17: ...dirt 5 The printer is out of paper Check if the printer has any paper 6 Replace the printer paper The printer has been installed with printer paper If the printing paper is used new printing paper wi...

Page 18: ...ithin one year from the date of purchase the product quality problem free warranty life long maintenance and technical services If it is found that the instrument is not normal or defective please con...

Reviews: