2.2.3 Camera configuration
①ADDRESS switch
②PROTOCOL switch
③BAUDRATE switch
④RS-422/RS-485 switch
⑤TERMINATION switch :
- ON :
- OFF :
⑥SAFETY FUSE :
- It is to set camera ID to connect multiple cameras.
- Max. 255 of camera IDs(as binary notation) are available.
- Camera ID setting is as described on <Table. 5>.
- Protocol can be set manually or automatically.
- Upon selecting "Protocol Auto Detection" function, protocol will be selected automatically.
- PROTOCOL setting is as described on <Table.1>.
- Select baud rate.
- Baud rate setting is as described on <Table 2>.
- RS-422 or RS-485 is selectable for remote control between camera and controller.
- RS-422/RS-485 switch setting is as described on <Table 3>.
Used for RS-485/RS-422 connection
Set on the last camera for 1:1 or multi communication between Camera and
PC or a controller.
Set on all cameras except for the last camera for multi-communication.
- TERMINATION setting is as described on <Table 4>.
It prevents overflow of electricity for safety.(250V, 3A)
14
[Pic 1] DIP SWITCH
DETAIL "A"
Chapter 2. Overview and How to install
①
⑥
③
④
⑤
②
"A"