5
• The sauna stove must be installed on a non-combustible surface
with the required carrying capacity.
• Electrical equipment and wiring are not permitted in the safety
areaf the sauna stove.
Table 1 Power
kW
Room
A
B
inches
C
inches
D
inches
E
inches
F
inches
Ø
inches
H
inches
HIVE Heat
12/
LS
12
6-13 m
3
211.9 -
459.1 ft
3
170 mm
6.7 in
500 mm
19.7 in
240 mm
9.5 in
425 mm
16.8 in
5 mm /
155 mm
0.2 in /
16.1 in
300 mm
450 mm
11.9 in
/
17.8 in
450 mm
17.8 in
750 mm
29.6 in
Installing Hive Heat 12
LS
to be heated from another room
• The furnace bushing of the sauna stove must be made through a
non-combustible wall (stone, concrete, etc.).
• The furnace bushing of the sauna stove must be made through
a non-combustible wall (stone, concrete, etc.) that extends 600
mm / 23.63 in to the sides of and 1,400 mm / 55.1 in above the
opening.
• It is advisable to leave a 50 mm / 2 in air gap between the bushing
and thestove; therefore, add 100 mm / 4 in to height
D
and width
C
given in table 1 when calculating the dimensions for the open-
ing.
• If the floor in front of the furnace is made from combustible
material, fire-resistant floor protection must be installed in front