background image

Declaration of Performance /Leistungsdeklaration

Product type /

Produkt

HUUM Sauna OÜ

Intended /

Vorgesehen

51014, Estonia

The product conforms to the 
following standards /

Das

Produkt steht zu folgenden
Bedingungen

Notified body (identification
number)/

Anmeldung 

(Identifikationsnummer) 

Performance /

Leistung

Harmonised
technical 
specification /

Harmonisierte 
technische 

Pass 1) /

 Erfüllt 1)

to ceiling /

Decke

1200

to sides /

auf Seiten

170

to front /

Vorderseite

500

to back /

Rückseite

170

Pass/

 Erfüllt

Pass /

 Erfüllt

NPD
Pass /

Erfüllt

292°C
Pass / Erfüllt
12kW
918 mg/m3
0,074%
22 mg/m3
74%
12Pa

3,6kg x3 (max 30cm)

closed /

 zu

Pass /

 Erfüllt

13,3g/s

*Stove door closed / Tür geschlossen
NPD=no performance determinated / NPD- keine Leistung
1) installation of the stove only on non combustible floor or base 
1) die Installation des Ofens nur auf dem nichtbrennbaren Boden

Tartu, Estonia, 01.10.2019

Siim Nellis

CEO

[email protected]

Release of dangerous substances /

Abgabe gefährliche Stoffe

Safety distances to combustible materials (mm) /       

Sicherheitsabstände zu brennbaren Materialien (mm)

Ignition load and refuelling loads /       

Zündlast und Brennstoffaufgabemenge

Ash box gap after ignition phase /       

Der Spalt der Aschebox nach Zündung

Dust emission  at 13% O2 (mg/m3) /

Staub 13 % O2

Mechanical resistance /

Mechanische Beständigkeit

Thermal output /

Thermische Leistung

Carbon monoxide emission at 13% O2 /

CO-Emission 13 % O2

Total efficiency /

Wirkungsgrad

Flue draught * /

Förderdrück*

Declared performance /

Erklärte Leistung

EN 15821:2010

Carbon monoxide emission at 13% O2 /

CO-Emission 13 % O2

HEAT 12

Emission of combustible products /   

Emission von unbrennbaren Stoffen

Fire safety (initiation, risk to adjacent) /       

Brandsicherheit (Brandgefahr der angrenzenden Bauteile) 

Products are tested in accordance to the methods 
described in the standard EN 15821:2010 /

Die Produkte 

sind mit Methoden vom Standard EN 15821:2010 getestet
worden.  

Multi-firing sauna stove fired by natural wood logs

Mehrfach befeuerbarer Ofen (Scheitholz)

TÜV SÜD Industrie Service GmbH; Ridlestrasse 65, 80339
Munich, Germany (0036)

Essential Characteristic /       

Grundlegende Eigenschaften

Durability /

Dauerhaftigkeit

Flue gas mass flow* /

Rauchgasmassenstrom*

Surface temperature /

Oberflächentemperatur

Cleanability /

Reinigungsmöglichkeit

Flue gas average temperature* /

Abgastemperatur*

Déclaration de performance

Type de produit

Utilisation envisagée

Le produit est conforme aux 

normes suivantes

Organisme notifié (numéro 

d’identification)

Poêle de sauna à foyer mixte alimenté en bois massif

Les produits sont testés conformément aux méthodes 

décrites dans la norme EN 15821:2010 

TÜV SÜD Industrie Service GmbH; Ridlestrasse 65, 80339 

Munich, Allemagne (0036) 

Performance déclarée

Caractéristique essentielle

Performance

Spécifications 

techniques 

harmonisées

Sécurité anti-incendie (allumage, risque pour les éléments adjacents) Admis 1)

Distances de sécurité par rapport aux matériaux combustibles (mm)

du plafond
des côtés
de l’avant
de l’arrière 

Émissions des produits combustibles

Admis

Admis

Admis

Admis

Température de surface 
Rejet de substances dangereuses
Facilité de nettoyage
Température des gaz de combustion*
Résistance mécanique
Puissance de chauffe

Émissions de monoxyde de carbone à 13 % O2

Émissions de monoxyde de carbone à 13 % O2
Émissions de poussières à 13 % O2 (mg/m3)

Rendement total

Tirage de cheminée*

Charge d’allumage et charges de ravitaillement

Position du bac à cendres après la phase d’allumage

fermée

Admis

Durabilité
Débit massique des gaz de combustion*

* Porte du poêle fermée

NPD = aucune performance déterminée

1) installation du poêle uniquement sur un sol ou un socle non combustible

Tartu, Estonie, 01.10.2019

Siim Nellis 

Directeur général

[email protected]

HUUM Sauna OÜ

51014, Estonie

FRA

Summary of Contents for HIVE HEAT

Page 1: ...SAUNA HEATER HIVE HEAT info huumsauna com www huumsauna com PO LE DE SAUNA FRA...

Page 2: ...Materialien mm Ignition load and refuelling loads Z ndlast und Brennstoffaufgabemenge Ash box gap after ignition phase Der Spalt der Aschebox nach Z ndung Dust emission at 13 O2 mg m3 Staub 13 O2 Mech...

Page 3: ...s 12kW and 12kW LS Follow the instructions for your model carefully Important The sauna stove described in these instructions should only be connected to the chimney by a specialist The Hive Heat saun...

Page 4: ...ers LS in these instructions Weight of the sauna stove 56 kg 123 5 lb Minimal diameter of ventilation openings 78 5 cm2 0 8 ft2 Size of the steam room 6 m3 13 m3 211 9 ft3 459 1 ft3 Minimal diameter o...

Page 5: ...veHeat12LStobeheatedfromanotherroom The furnace bushing of the sauna stove must be made through a non combustible wall stone concrete etc The furnace bushing of the sauna stove must be made through a...

Page 6: ...stove can only be connected to the chimney by spe cialists The flue gases of the stove must be directed into a separate flue Use of a common flue with other furnaces is not permitted Important Forced...

Page 7: ...ed bycontrolling the draught of the air vents in the front side of the heater by changing the position of the shutter It is recommend edto keep the ash tray open by up to 2 mm 0 1 in for ignition Duri...

Page 8: ...ht Ifthesaunahasnotbeenusedforalongtime haveaspecialistcheck thefurnace grateandashtrayconditionbeforeheatingthesauna stove Ifnecessary arrangefortheconditionofthechimneyandthe fluetobecheckedaswell A...

Page 9: ...placing the product Demands must be made not later than 5 years after buying the product Purchase receipt needs to be presented when warranty demands are made Warranty Terms Warranty applies only to h...

Page 10: ...as not been installed correctly product has been modified in any way warranty period is over product is not complete All demands shall be presented directly to HUUM Sauna O address Vinkli tn 2 Tartu 5...

Page 11: ...11...

Page 12: ...the methods described in the standard EN 15821 2010 Die Produkte sind mit Methoden vom Standard EN 15821 2010 getestet worden Multi firing sauna stove fired by natural wood logs Mehrfach befeuerbarer...

Page 13: ...ivement les instructions de votre mod le Important Seul un professionnel est autoris raccorder un conduit de chemin e le po le de sauna d crit dans ces instructions Le kit de livraison du po le de sau...

Page 14: ...ir entre des po les de puissance nominale diff rente Le po le peut tre quip d un appareil de production d eau chaude et d un raccord mural pour foyer ce qui est indiqu par les lettres LS dans les pr s...

Page 15: ...tu de mat riaux combustibles un r flecteur de chaleur doit tre plac entre le sol et le po le Aucun appareil lectrique ou c ble ne doit se trouver dans le p rim tre de s curit du po le de sauna Tableau...

Page 16: ...ccord au conduit de chemin e par des tuyaux m talliques sp ciaux qui sont le cas ch ant scell s avec des joints r sistants la chaleur Les coudes de raccordement doivent avoir un faible rayon de courbu...

Page 17: ...ntit de combustible compos e de petits morceaux de mat riaux facilement inflammables et de ce fait moins dense et plus l g re que le reste de la quantit de combustible Le po le de sauna ne peut tre ch...

Page 18: ...est d conseill de jeter de l eau dure ou trop riche en fer sur le po le de sauna NB Ne pas d passer le taux d humidit indiqu sur le graphique lors de la production de vapeur Entretien du po le Ilestre...

Page 19: ...esconduitss imposeaumoinsune foisparan Touteslesr glementationslocalesanti incendieapplicablesau nettoyagedesappareilsdechauffagedoivent trerespect eslors dunettoyagedupo ledesauna GARANTIE L acheteur...

Page 20: ...s l usure ou les d fauts caus s par une mauvaise utilisation du produit La garantie ne s applique pas lorsque la d fectuosit est due au transport ou une autre cause trang re au fabricant l endommageme...

Page 21: ...21 REMARQUES NOTES...

Page 22: ...huumsauna www huumsauna com...

Reviews: