EGPF Merchandisers
P/N 3143042_B 2-9
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
DETAIL A
TOP LEFT SIDE OF CASE
SCALE 1:1.33
1.50
APPROX
1.50
APPROX
VIEW OF TOP OF CASE
HACCP
SENSOR
THERMOMETER
SENSOR
DISCHARGE AIR
SENSOR
FRONT OF CASE
TOP LEFT DEFLECTOR ONLY
GETS 3 SENSORS
SEE DETAIL A
DEFLECTOR
DISCHARGE
OPTIONAL SOLAR
THERMOMETER
SENSORS ATTACH TO UNDERSIDE OF
DEFLECTOR DISCHARGE AS SHOWN
LOOKING AT TOP FRONT
LEFT SIDE OF CASE
SENSORS MUST BE
INSTALLED IN
POSITIONS SHOWN
LEFT
SIDE
OF
CASE
TOP PANEL
THERMOMETER
HOLE
A
ROUTE SENSOR WIRING UNDER
TOP FOAM PANEL TILL BUSHING
IN LH FAN PLENUM AS SHOWN
REFER SHEET-2 & 3 FOR FURTHUR ROUTING
TO TOP OF CASE
GDF
3.
0
SH
EET
S
IZ
E
D
SHEET 2 OF 6
3141403
A
INSTRUCTION-ELEC WIRE
ROUTING EGPF-MT
P/N
REV
THIRD
ANGLE
PROJECTION
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES.
R
PARTIAL FRONT VIEW
FAN PLENUM MODULE ONLY
INTR PANELS AND OTHER HIDDEN FOR CLARITY
SCALE 1:6.67
FAN HARNESS ROUTED TO TOP
A
ROUTE
FAN HARNESS FOR 12FT CASE
FAN HARNESS FOR 8FT CASE
THIS END CONNECTED TO POWER
SUPPLY IN ELEC BOX
THIS END CONNECTED TO FSS IN TOP ELEC ENCLOSURE
SENSOR WIRE ROUTED TO TOP
OF THE CASE AS SHOWN
FAN WIRING ROUTE
SENSOR CANOPY LOCATION