![Hussmann SGN141S-1 Installation & Maintenance Manual Download Page 16](http://html1.mh-extra.com/html/hussmann/sgn141s-1/sgn141s-1_installation-and-maintenance-manual_2189237016.webp)
SGN141S-1 R290 Self-Contained Low Height Open Refrigerated Display Cabinet
Manual
Ju
ly
2021 Final Rev: 30A01
16
11. Clean bumpers and any plastic parts with a soft cloth and mild detergent, then wipe dry with
a clean cloth.
Replace base trays and shelves and turn on power.
13. Allow the case to attain correct working temperature (approx. 30 minutes) and restock the
shelves.
NOTE: After cleaning, make sure to clean the area around the case to prevent slips and falls
Monthly
A thorough condenser air filter check, and clean if dirty, should be carried out monthly by store
personnel. If condenser air filter is dirty, then the following procedures should be undertaken as a
minimum:-
1. The front lower panel holding the condenser air filter is held in position magnetically, it is
easy to remove by pulling this panel forward. Refer to photo sequence inserted further
below. NOTE:- no tools are required to remove or replace the condenser air filter panel or
filter.
2. Use appropriate PPE.
3. Make area safe, ideally this task should be undertaken when the store is closed to
customers and undergoing cleaning and/or re-stocking.
4. Remove condenser air filter panel.
5. Remove condenser air filter media/mesh.
6. Take to the back-of-house or an area where filter media/mesh can be undertaken
appropriately.
7. If available use a vacuum cleaner with a soft brush and thoroughly clean the filter.
8. If no vacuum cleaner, then washing in warm water is recommended. Ensure the filter is at
least shaken dry (i.e. no water drips).
9. Return now clean filter to the cabinet and replace in reverse order. Ensure filter
media/mesh is correctly positioned and that the filter panel is re-fitted in its correct
position.
10. Photo sequence of above steps in task order follows:-
a.
Front Panel
removal