![Hussmann RHR 1/2 HEX Installation And Operation Manual Download Page 8](http://html.mh-extra.com/html/hussmann/rhr-1-2-hex/rhr-1-2-hex_installation-and-operation-manual_2189841008.webp)
IGHT-RHR, RHR2-HEX-9911
8
Case Specifications
# OF
# OF
# OF
CIRCUIT 1
CIRCUIT 2
MODEL
LENGTH
WELLS
GRIDDLES
SHELVES
VOLTS
PHASE
Loads
PHASE
Loads
RHR-HEX
4'-0"
––
1
—
208
1Ø
17
240
1Ø
19
6'-0"
––
1
—
208
3Ø
21
240
3Ø
24
RHR-HEX-2
4'-0"
––
2
1
208
1Ø
16
240
1Ø
18
6'-0"
––
2
1
208
3Ø
23
240
3Ø
27
RHR-Square
4'-0"
––
1
—
208
1Ø
18
240
1Ø
18
6'-0"
––
1
—
208
Pending
Design
240
Pending
Design
RHR-1/2 HEX
4'-0"
––
1
208
1Ø
9
240
1Ø
10
6'-0"
––
1
208
1Ø
17
240
1Ø
19
NOTES:
These merchandisers have been designed for use in stores where temperatures and humidity are maintained at or below 75
°
F and 55%RH. Stores are
responsible for setting their cases appropriately in conditions which vary from the above. The number of defrosts and/or the duration may vary for cases
displaying products for which they were not designed. Italicized data indicates optional equipment.
• Hussmann Chino reserves the right to change or revise case specifications and design in connection with any feature of our products. Such changes do not entitle
the buyer to corresponding changes, improvements, additions, or replacement of equipment previously sold or shipped. These changes may also affect the loads
applicable to a particular case, therefore always check the serial plate at the back of the case and/or consult the factory for the current loads for your particular
equipment.
HUSSMANN CHINO CASE SPECIFICATIONS 11/99
I
NQUIRIES?
Technical
(800) 395-9229 X2133
Service
(800) 395-2320
Parts and Warranty Information
(800) 395-9229 X2131