background image

Electrical Data

Number of Fans

PWWEE

Refrigeration — 9W

1

Refrigeration — 9W (Export)

1

Amperes

Watts

Merchandiser

PWWEE

PWWEE

Fans (Refrigeration)

Standard (120V 60Hz)

0.77

62

Energy Efficient (120V 60Hz)

0.38

25

Export (230V 50 Hz)

0.47

70

Min. Circuit Ampacity

With Standard Fans (120V 60Hz)

0.97

With Energy Efficient Fans (120V 60Hz)

0.58

With Export Fans (230V 50 Hz)

0.67

Maximum Over Current Protection 120V

20

Maximum Over Current Protection 230V

15

Standard Lighting

Optional Lighting

Optional Shelf Lighting

None

None

None

PWREE 

Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

4 of 4

Impact  

PWREE

Produce

=  120V P

OWER

=  120V N

EUTRAL

Fan  Wiring
Offtime Defrost

WARNING

All components must have a mechanical ground, and the merchandiser must be grounded.

CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS

    

1 Fan

120V N

EUTRAL

B

ROWN

  B

AND

120V P

OWER

Fan

1

B

ROWN

  B

AND

Summary of Contents for PWREE

Page 1: ...scription Wiring Item FAN ASSEMBLIES AND THERMOSTATS A 0378349 Fan Motor Evaporator 1 0142780 Fan Blade Embossing toward motor We reserve the right to change or revise specifications and product design in connection with any feature of our products Such changes do not entitle the buyer to corresponding changes improvements additions or replacements for equipment previously sold or shipped ...

Page 2: ...aximum outside dimension of case side to side includes bumper 98 1 2 2502 Lefthand side of case to outside edge of righthand base rail 81 1 2 2070 Width of case 49 3 8 1254 Front of base rail to rear of case 32 3 8 822 Front of case to outside edge of base rail 17 432 Front of splashguard to outside edge of base rail 5 7 8 149 Width of base rail 2 1 8 54 Access area between front of base rail and ...

Page 3: ...Discharge Air F 32 Evaporator F 24 Unit Sizing F 22 Btu hr case PWREE Parallel 2845 Conventional 3140 For all refrigeration equipment other than Hussmann use conventional Btu values DEFROST DATA PWREE Frequency hr 6 Defrost Water lb ft day 8 15 based on case configuration and product loading OFFTIME PWREE Temp Term F N A Failsafe minutes 45 CONVENTIONAL CONTROLS Low Pressure Backup Control CI CO 1...

Page 4: ...8 With Export Fans 230V 50 Hz 0 67 Maximum Over Current Protection 120V 20 Maximum Over Current Protection 230V 15 Standard Lighting Optional Lighting Optional Shelf Lighting None None None PWREE Data Sheet HUSSMANN CORPORATION Bridgeton MO 63044 2483 U S A 4 of 4 Impact PWREE Produce 120V POWER 120V NEUTRAL Fan Wiring Offtime Defrost WARNING All components must have a mechanical ground and the me...