background image

PWREE 

Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

2 of 4

PWREE

Base Rail

Waste Outlet

& Water  Seal

Front

Access Area

32

 

3

/

8

(822)

49

 

3

/

8

(1254)

17

(432)

81

 

1

/

2

(2070)

98

 

1

/

2

(2502)

38

 

3

/

4

(984)

17

(432)

5

 

7

/

(149)

26

 

1

/

4

(667

)

5

 

7

/

(149)

Engineering

Plan Views

End Case

for 98 Inch

Produce

Wide Island

07-2003

Dimensions are shown as inches & (mm).

General

END

PWREE

Maximum outside dimension of case side to side 

(includes bumper)

98 

1

/

2

(2502)

Lefthand side of case to outside edge of righthand base rail

81 

1

/

2

(2070)

Width of case

49 

3

/

8

(1254)

Front of base rail to rear of case

32 

3

/

(822)

Front of case to outside edge of base rail

17 (432)

Front of splashguard to outside edge of base rail

7

/

8

(149)

Width of base rail

1

/

8

(54)

Access area between front of base rail and splashguard

7

/

8

(124)

Waste Outlet

Front outside edge of case to center of waste outlet

26 

1

/

4

(667)

Right outside edge of case to center of waste outlet

38 

3

/

4

(984)

Summary of Contents for PWREE

Page 1: ...scription Wiring Item FAN ASSEMBLIES AND THERMOSTATS A 0378349 Fan Motor Evaporator 1 0142780 Fan Blade Embossing toward motor We reserve the right to change or revise specifications and product design in connection with any feature of our products Such changes do not entitle the buyer to corresponding changes improvements additions or replacements for equipment previously sold or shipped ...

Page 2: ...aximum outside dimension of case side to side includes bumper 98 1 2 2502 Lefthand side of case to outside edge of righthand base rail 81 1 2 2070 Width of case 49 3 8 1254 Front of base rail to rear of case 32 3 8 822 Front of case to outside edge of base rail 17 432 Front of splashguard to outside edge of base rail 5 7 8 149 Width of base rail 2 1 8 54 Access area between front of base rail and ...

Page 3: ...Discharge Air F 32 Evaporator F 24 Unit Sizing F 22 Btu hr case PWREE Parallel 2845 Conventional 3140 For all refrigeration equipment other than Hussmann use conventional Btu values DEFROST DATA PWREE Frequency hr 6 Defrost Water lb ft day 8 15 based on case configuration and product loading OFFTIME PWREE Temp Term F N A Failsafe minutes 45 CONVENTIONAL CONTROLS Low Pressure Backup Control CI CO 1...

Page 4: ...8 With Export Fans 230V 50 Hz 0 67 Maximum Over Current Protection 120V 20 Maximum Over Current Protection 230V 15 Standard Lighting Optional Lighting Optional Shelf Lighting None None None PWREE Data Sheet HUSSMANN CORPORATION Bridgeton MO 63044 2483 U S A 4 of 4 Impact PWREE Produce 120V POWER 120V NEUTRAL Fan Wiring Offtime Defrost WARNING All components must have a mechanical ground and the me...