background image

3 of 4

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

P/N 0417993A

Impact  

PWREE

Produce

Produce Wide Island End, 1 Display Level

44

(1118)

30 

3

/

8

(772)

15

(381)

36 

3

/

4

(933)

(152)

12 

3

/

8

(314)

7

/

8

(149)

17 

(432)

49 

3

/

(1254)

16 

5

/

8

(422)

26 

1

/

4

 

(667)

32 

3

/

8

 

(822)

25 

1

/

2

(648)

17 

3

/

8

(441)

FAN 

COIL 

PWREE

Optional

Rack

Positions

NSF Certification

These merchandisers are manufactured to meet ANSI /National
Sanitation Foundation (NSF

®

) Standard #7 requirements.

Dimensions are shown as inches & (mm).

REFRIGERATION DATA

Note: 

This data is based on store temperature

and humidity that does not exceed 75

°

F and

55% R.H.

PWREE

Discharge Air (°F)

32

Evaporator(°F)

24

Unit Sizing (°F)

22

Btu/hr/case*

PWREE

Parallel

2845

Conventional

3140

*

For all refrigeration equipment other than

Hussmann, use conventional Btu values.

DEFROST DATA

PWREE

Frequency (hr)

6

Defrost Water (lb/ft/day)

8

(± 15% 

based on case configuration and

product loading).

O

FFTIME

PWREE

Temp Term (°F)

N/A

Failsafe (minutes)

45

CONVENTIONAL  CONTROLS

Low Pressure Backup Control

CI/CO**

17°/ 7° F

Indoor Unit Only, Pressure Defrost

Termination**

48° F

**Use a Temperature Pressure Chart to
determine PSIG conversions.

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

1

/

2

Liquid Line (in.)

3

/

8

Suction Line (in.)

7

/

8

Estimated Charge (lb)***

1.1

***This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.

Length Added to Lineup by

Each End/Partition (in.)

1

/

2

Summary of Contents for PWREE

Page 1: ...scription Wiring Item FAN ASSEMBLIES AND THERMOSTATS A 0378349 Fan Motor Evaporator 1 0142780 Fan Blade Embossing toward motor We reserve the right to change or revise specifications and product design in connection with any feature of our products Such changes do not entitle the buyer to corresponding changes improvements additions or replacements for equipment previously sold or shipped ...

Page 2: ...aximum outside dimension of case side to side includes bumper 98 1 2 2502 Lefthand side of case to outside edge of righthand base rail 81 1 2 2070 Width of case 49 3 8 1254 Front of base rail to rear of case 32 3 8 822 Front of case to outside edge of base rail 17 432 Front of splashguard to outside edge of base rail 5 7 8 149 Width of base rail 2 1 8 54 Access area between front of base rail and ...

Page 3: ...Discharge Air F 32 Evaporator F 24 Unit Sizing F 22 Btu hr case PWREE Parallel 2845 Conventional 3140 For all refrigeration equipment other than Hussmann use conventional Btu values DEFROST DATA PWREE Frequency hr 6 Defrost Water lb ft day 8 15 based on case configuration and product loading OFFTIME PWREE Temp Term F N A Failsafe minutes 45 CONVENTIONAL CONTROLS Low Pressure Backup Control CI CO 1...

Page 4: ...8 With Export Fans 230V 50 Hz 0 67 Maximum Over Current Protection 120V 20 Maximum Over Current Protection 230V 15 Standard Lighting Optional Lighting Optional Shelf Lighting None None None PWREE Data Sheet HUSSMANN CORPORATION Bridgeton MO 63044 2483 U S A 4 of 4 Impact PWREE Produce 120V POWER 120V NEUTRAL Fan Wiring Offtime Defrost WARNING All components must have a mechanical ground and the me...