1-2
I
NSTALLATION
P/N 0378414G
EXTERIOR LOADING
Do NOT walk on top of merchandisers
or
damage to the merchandisers and serious
personal injury could occur.
T
HEY ARE NOT
STRUCTURALLY DESIGNED TO SUPPORT EXCESSIVE
EXTERNAL LOADING
such as the weight of a
person. Do not place heavy objects on the case.
MERCHANDISERS SHIPPED
WITH END INSTALLED
If the case was shipped with the end installed,
two long bolts were used to hold the shipping
brace to the end. If the shipping bolts are
reinserted after removing the brace, they will
extend into the product area. T
HEREFORE
,
BE
SURE TO REPLACE THESE BOLTS WITH THE SHORTER
BOLTS PROVIDED
. NSF requires any bolt or screw
in the product area be capped or cut off if it has
more than three exposed threads.
NOTE:
Be careful not to damage the factory
installed end while moving the case.
Make sure that tools are positioned past
the end and beneath the merchandiser’s
support bar.
SHIPPING BRACES
Move the merchandiser as close
as possible to its permanent
location and then remove all
packaging. Check for damage
before discarding packaging.
Remove all separately packed
accessories such as kits and
shelves.
LEVELING
Merchandisers must be installed level to ensure
proper operation of the refrigeration system and
to ensure proper drainage of defrost water. When
leveling merchandisers, use a carpenter’s level as
shown. Leveling shims are provided with each
merchandiser for use if needed. The shims are big
enough so that you can level adjoining merchan-
disers at the same time using one shim.
NOTES:
• B
EGIN LINEUP LEVELING FROM THE HIGHEST POINT
OF THE STORE FLOOR
.
• If shimming two corners, check to see if a shim is
needed in the center of the merchandiser. If a gap
exists between the support rail of the merchandiser
and the floor, a shim should be placed in the center.
Do NOT remove shipping braces until
the merchandisers are positioned
for installation.
WARNING
!
Rear
Levels
Serial Plate
Front of
Merchandiser