background image

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

P/N 0412043A

Note: 

Changed items have been underlined.

Merchandisers

®

B

D

C

A

E

D

E

E

E

C3LGE

Data Sheet Set

P/N 0412043A

NSF

®

Certified

August  2004

Item Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES AND

T

HERMOSTATS

A.

9W

Fan Assembly

(1)

0047000

Fan Motor, Evaporator 

0315470

Fan Blade
embossing toward motor

B. 0411744

Standard Non-adjustable

(2)

Defrost Thermostat

C. 0137880

Optional Adjustable 

(3)

Refrigeration Thermostat

Item Part #

Description

Wiring Item #

L

AMPS AND

B

ALLASTS

D. 0428648

Ballast, Electronic

2 lamps

(4)

D. 0428649

Ballast, Electronic

3 lamps

(4)

E.

Fluorescent Lamp

(5)

Replace with like fixtures

Summary of Contents for IMPACT Excel C3LGE

Page 1: ...ing Item FAN ASSEMBLIES AND THERMOSTATS A 9W Fan Assembly 1 0047000 Fan Motor Evaporator 0315470 Fan Blade embossing toward motor B 0411744 Standard Non adjustable 2 Defrost Thermostat C 0137880 Optio...

Page 2: ...rthest knockout 88 3 8 2245 136 1 2 3467 Back of case to center of knockout 35 3 8 899 35 3 8 899 Length of electrical raceway 34 5 8 878 34 5 8 878 Waste Outlet C RH End of case to the center of wast...

Page 3: ...tion and product loading OFFTIME C3LGE Temp Term F 48 F Failsafe Minutes 30 ELECTRIC OR GAS Not Recommended Standard Defrost Thermostat Close on rise close 48 F open 33 F CONVENTIONAL CONTROLS Low Pre...

Page 4: ...eaters NA Minimum Circuit Ampacity With Standard Fans 120V 60Hz 1 60 2 30 With Energy Efficient Fans 120V 60Hz 0 96 1 34 Export 230V 50Hz 0 96 1 34 Maximum Over Current Protection 120V 20 20 Maximum O...

Page 5: ...must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost Case GROUND Connector Connector G Connector Connector Connector Co...

Page 6: ...AND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 Standard Lighting 1 Row Canopy or Optional 1 Row Rail Light Circuits Optional Lighting 2 Rows Canopy WARNING All components must have...

Page 7: ...e of peg shelves is NOT recommended on C3LGE cases Depth and angle requirements are listed below Top Shelf Shelf Depth Shelf Angle 12 inches 0 10 15 30 45 14 inches 30 45 Second Shelf Shelf Depth Shel...

Page 8: ...ng case of the merchandiser To access the ballast 1 Remove screws from the front lip of light tray flange covering the bottom edge of the canopy Also remove screws located near the middle rear of ligh...