OPERATION and NORMAL MAINTENANCE                   
 
 
TEMPERATURE CONTROL –  
 
 

The temperature control which senses the cold wall temperature is located at 

the side of the case. Adjustment of the control is done by turning the knob clockwise 
for colder temperatures and counterclockwise for warmer temperatures. 
 
 
 
 
 
 
 
 
 
 
 
 
 
                                                                
 

The control is adjustable for both Freezer and Refrigerator Temperatures. 

Towards the Maximum Zone are freezing temperatures and towards the Minimum 
Zone are refrigerator temperatures. Due to the case design, once an adjustment is 
made some time will lapse before the temperature inside the fixture reacts to the 
change. 
 
DEFROSTING –  Disconnect Power Supply Before Starting -  
 
 

Defrosting is accomplished manually by scraping frost from areas where it 

has collected on the cabinet interior.  Remove excess ice and water.  After washing 
and drying thoroughly reconnect the power supply. 
 

 

CONDENSING UNIT –  
 
 

On Models so equipped, check occasionally to assure that the condenser fan 

motor in the compressor area is operating properly. This motor assists in the cooling 
process and also keep the compressor cool for longer life. 
 

Summary of Contents for HBD/BC-142

Page 1: ...s Sliding Glass Top Solid Top Freezer Cooler Chests Curved Top Y Interior Step Flat Top Interior Step Flat Top P Flat Interior Solid Top H Interior Step Hussmann Corporation 12999 St Charles Rock Road...

Page 2: ...pacities 4 Refrigerant and Refrigerant Charges 5 Installation and Start Up Leveling Casters Baskets 6 Drain and Power Cord 7 Temperature Control and Defrosting 8 Cleaning Condenser 9 Cleaning Exterior...

Page 3: ...remove shipping crate and examine cabinet for concealed damage If damage is found contact the delivering carrier immediately and have his agent prepare an inspection report for the purpose of filing a...

Page 4: ...1 20 6 HSD SC 162P 33 9 21 3 36 3 28 7 16 1 20 6 HSD SC 192P 38 8 21 3 36 3 33 7 16 1 20 6 HSD SC 218P 42 5 21 3 36 3 37 4 16 1 20 6 HBD BC 142H 28 9 21 3 33 8 23 8 16 1 25 6 HBD BC 160H 31 5 21 3 33...

Page 5: ...nge from time to time R 134a HSD SC 190Y Curved Glass Top 5 64oz HSD SC 220Y Curved Glass Top 6 35oz HSD SC 280Y Curved Glass Top 7 05oz HSD SC 320Y Curved Glass Top 8 11oz HSD SC 258 Flat Top Int Ste...

Page 6: ...sters have a lock in place feature To activate the locking mechanism push down firmly on the plastic flange that protrudes from the caster To unlock the caster pull up on the flange The casters are of...

Page 7: ...product loss due to overloading or malfunction of other equipment on the same circuit Use a 15 amp time delay fuse The supply circuit must conform to National and local electrical codes A wiring diagr...

Page 8: ...refrigerator temperatures Due to the case design once an adjustment is made some time will lapse before the temperature inside the fixture reacts to the change DEFROSTING Disconnect Power Supply Befo...

Page 9: ...NTERIOR For cleaning the interior of the liner storage area a flush out drain has been provided on the case floor to assist in getting rid of any water in the bottom of the case Disconnect the electri...

Page 10: ...artment opening 7 Defective condenser fan motor 7 Replace High head pressure 1 Cabinet location too warm 1 Relocate cabinet remove air flow restriction 2 Defective condenser fan motor 2 Replace 3 Air...

Page 11: ...art number is not known give a clear description of part itself and its function in the cabinet or remote unit Warranty Parts Procedure Same as items above Give original installation date of cabinet a...

Page 12: ...iding Glass Door Lower HSD SC 408 5 HM 1005 Sliding Glass Door Lower HSD SC 518 5 HM 1006 Sliding Glass Door Lower HSD SC 190Y 5 HM 1007 Sliding Glass Door Lower HSD SC 220Y 5 HM 1008 Sliding Glass Do...

Page 13: ...62P 192P 218P 5 HM 12007 Keyes for Lid Lock HSD SC 190Y 220Y 280Y 320Y 5 HM 12008 Keyes for Lid Lock HBD BC 142H 160H 180H 195H HBD BC 215H 258H 302H 5 HM 13001 Opt Light Fuse 2 Amp Curved Glass with...

Reviews: